EUVIMEDObjevte EUVIMED
Crossref

Highly Sensitive Fiber Pressure Sensors over a Wide Pressure Range Enabled by Resistive-Capacitive Hybrid Response

Xiangyang Qu, Jing Li, Zhiliang Han, Qianqian Liang, Zhou Zhou, Ruimin Xie, Huaping Wang, Shiyan Chen iD

ACS Nano · 2023-08-08 · 17 (15) · 14904-14915

DOI: 10.1021/acsnano.3c03484 ↗

At a glance

Journal article in ACS Nano, published online on 2023-07-27. Written by Xiangyang Qu and 7 co-authors. Institution: State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Sha…. Cited 84 times so far (Crossref); 49 references. Funded by: National Natural Science Foundation of China.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Soft capacitive pressure sensors with high performance are becoming increasingly in demand in the emerging flexible wearable field. While capacitive fiber pressure sensors have achieved high sensitivity, their sensitivity range is limited to low-pressure levels. As fiber sensors typically require preloading and fixation, this narrow range of high sensitivity poses a challenge for practical applications. To overcome this limitation, the study proposes resistive-capacitive hybrid response fiber pressure sensors (HFPSs) with three-layer core-sheath structures. The trigger and sensitivity enhancement mechanisms of the hybrid response are determined through model analysis and experimental verification. By adjustment of the sensitivity enhancement range of the hybrid response, the sensitivity attenuation of HFPSs is alleviated significantly. The obtained results demonstrate that HFPSs have excellent characteristics such as fast response, low hysteresis, wide response frequency, small signal drift, and good durability. The hybrid response enhances the practical sensitivity of HFPSs for various applications. With enhanced sensitivity, HFPSs can effectively monitor pulse signals at preloads ranging from 0 to 22.7 kPa. This wide range of preloads improves the fault tolerance of pulse monitoring and expands the potential application scenarios of fiber pressure sensors.

Subjects

Author keywords

capacitivefiberhybrid responsepiezoresistivepressure sensor

Authors and institutions

  • State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, PR China.

ORCID profiles: Shiyan Chen

Funding

  • National Natural Science Foundation of China

Cite

APA

Qu, X., Li, J., Han, Z., Liang, Q., Zhou, Z., Xie, R., Wang, H., & Chen, S. (2023). Highly Sensitive Fiber Pressure Sensors over a Wide Pressure Range Enabled by Resistive-Capacitive Hybrid Response. ACS Nano, 17(15), 14904-14915. https://doi.org/10.1021/acsnano.3c03484

Vancouver

Qu X, Li J, Han Z, Liang Q, Zhou Z, Xie R, et al. Highly Sensitive Fiber Pressure Sensors over a Wide Pressure Range Enabled by Resistive-Capacitive Hybrid Response. ACS Nano. 2023;17(15):14904-14915. doi:10.1021/acsnano.3c03484

BibTeX
@article{Qu2023,
  author = {Qu, Xiangyang and Li, Jing and Han, Zhiliang and Liang, Qianqian and Zhou, Zhou and Xie, Ruimin and Wang, Huaping and Chen, Shiyan},
  title = {Highly Sensitive Fiber Pressure Sensors over a Wide Pressure Range Enabled by Resistive-Capacitive Hybrid Response},
  journal = {ACS Nano},
  year = {2023},
  volume = {17},
  number = {15},
  pages = {14904--14915},
  doi = {10.1021/acsnano.3c03484}
}
Start for free →