EUVIMEDEUVIMED entdecken
Crossref

Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors

Zhengtao Hu, Jierui Zhao iD, Zhuokai Qu, Zachary Pizzo iD, Ke Li, Tony Zheng, Sijun Seong iD, Carlos A Figueroa Morales iD, Xiwen Gong iD

ACS Applied Materials & Interfaces · 04.11.2026 · 18 (43) · 59878-59885

DOI: 10.1021/acsami.6c13548 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 26.10.2026. Verfasst von Zhengtao Hu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan48109, United States. Die Arbeit nennt 33 Literaturangaben. Gefördert von: American Chemical Society Petroleum Research Fund, Horace H. Rackham School of Graduate Studies, University of Michigan, University of Michigan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Flexible capacitive pressure sensors (FCPSs) that resolve subtle pressure are central to soft robotics and human health monitoring. Their sensitivity is affected by microstructures incorporated at the interface between the electrode and dielectric layers, but fabricating fine artificial microstructures typically requires costly techniques. Biological templates offer a cost-effective way to form these microstructures, yet biotemplated FCPSs have remained limited in sensitivity. Efforts to improve sensitivity have predominantly focused on microstructure geometries, whereas the microstructure configuration in the sensor has not been well-studied. Here, we establish design insights for microstructure configurations through simplified computational analysis, revealing that amplifying the effective interelectrode distance variation rate and effective permittivity variation rate within the structured region is the key to enhancing overall sensitivity. Following this insight, we propose a dual-microstructure configuration that increases the air fraction within the structured region, leading to the amplified effective permittivity variation rate. Both computational and experimental assessments demonstrate that the dual-microstructure configuration outperforms conventional ones in sensitivity, with the fabricated sensor achieving the highest sensitivity of 4.3 kPa–1 among all the reported biotemplated FCPSs using the same dielectric materials (Table S1), along with a fast response/recovery time of 46/20 ms, a low detection limit of 1.2 Pa, and stable operation over 7500 cycles. These performance attributes enable the sensor for applications in robotic hand tactile sensing for soft objects and real-time physiological signal monitoring. Consequently, the proposed dual-microstructure configuration offers a generalizable pathway to enhance the sensitivity of biotemplated FCPSs, promoting the development of high-performance, cost-effective flexible pressure sensors.

Schlagwörter

Stichwörter der Autor:innen

biological templatedual microstructureflexible capacitive pressure sensorsrobotic handsensitivity

Autor:innen und Institutionen

  • Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan48109, United States.
  • Department of Chemical Engineering, University of Michigan, Ann Arbor, Michigan48109, United States.
  • Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan48109, United States.
  • Macromolecular Science and Engineering Program, University of Michigan, Ann Arbor, Michigan48109, United States.
  • Applied Physics Program, University of Michigan, Ann Arbor, Michigan48109, United States.

ORCID-Profile: Jierui Zhao, Zachary Pizzo, Sijun Seong, Carlos A Figueroa Morales, Xiwen Gong

Förderung

  • American Chemical Society Petroleum Research Fund
  • Horace H. Rackham School of Graduate Studies, University of Michigan
  • University of Michigan
  • National Science Foundation (NSF)
  • MNI-BI Neuroregeneration and Cognition Seed Fund

Zitieren

APA

Hu, Z., Zhao, J., Qu, Z., Pizzo, Z., Li, K., Zheng, T., Seong, S., Figueroa Morales, C. A., & Gong, X. (2026). Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors. ACS Applied Materials & Interfaces, 18(43), 59878-59885. https://doi.org/10.1021/acsami.6c13548

Vancouver

Hu Z, Zhao J, Qu Z, Pizzo Z, Li K, Zheng T, et al. Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors. ACS Applied Materials & Interfaces. 2026;18(43):59878-59885. doi:10.1021/acsami.6c13548

BibTeX
@article{Hu2026,
  author = {Hu, Zhengtao and Zhao, Jierui and Qu, Zhuokai and Pizzo, Zachary and Li, Ke and Zheng, Tony and Seong, Sijun and Figueroa Morales, Carlos A and Gong, Xiwen},
  title = {Dual-Microstructure Configuration Design Enabling Highly Sensitive Biotemplated Flexible Capacitive Pressure Sensors},
  journal = {ACS Applied Materials & Interfaces},
  year = {2026},
  volume = {18},
  number = {43},
  pages = {59878--59885},
  doi = {10.1021/acsami.6c13548}
}
Kostenlos starten →