EUVIMEDOpdag EUVIMED
Crossref

Interface Cleaning Strategy of Carbon Nanotube Field-Effect Transistor Biosensors for Ultrasensitive Detection of Ophthalmic Biomarkers

Zhibiao Zhu, Tingxian Li, Hai-Yang Liu, Fu-Xiao Luan, Zitan Pang, Yang Zhang, Jianping He, Jia Chen, Yong Tao, Mengmeng Xiao iD

ACS Applied Materials & Interfaces · 2025

DOI: 10.1021/acsami.5c04579 ↗

At a glance

Journal article in ACS Applied Materials & Interfaces, 2025. Written by Zhibiao Zhu and 9 co-authors. Institution: Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan, Hunan 411105, China. Major MEDLINE topics: Nanotubes, Carbon, Biosensing Techniques, Transistors, Electronic, Interleukin-6. Cited 7 times so far (Crossref); 50 references. Funded by: National Key Research and Development Program of China, National Natural Science Foundation of China, Xiangtan University.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Carbon nanotube (CNT) field-effect transistor (FET) biosensors combine the molecular recognition capabilities of bioreceptors with the signal amplification and transduction functions of nano-FET devices, enabling highly specific and ultrasensitive biomolecule detection. However, interface degradation and contamination introduced in the micronanofabrication process of batch manufacturing led to inhomogeneity in biofunctionalization of device and sensing performance, thus limiting the reproducible preparation and large-scale application of CNT FET biosensors. In this study, we proposed a comprehensive interface cleaning strategy using inductively coupled plasma oxygen (ICP-O2) and ozone (O3) treatment to reduce process contamination, which led to a 20% increase in transconductance, a 18.75% increase in carrier mobility, and near-theoretical-limit subthreshold swing (68 mV/dec) of CNT FET biosensors. Notably, the cleaning strategy facilitates the introduction of additional aptamer probe binding sites, thereby improving the sensitivity about 6.6-fold. We studied inflammatory related factors of ophthalmic diseases in clinical testing and found that our biosensors could detect trace level IL-6/IgE proteins in a complex tear matrix, with the limit of detection (LOD) reaching 1.37 aM and good consistency with the results of the enzyme-linked immunosorbent assay (ELISA). This study provides insights into the interface engineering of carbon-based FET biosensors and is expected to promote the practical application of CNT FET biosensors in the on-site detection of ophthalmic disease biomarkers.

Subjects

MeSH terms (MEDLINE)

Nanotubes, CarbonBiosensing TechniquesTransistors, ElectronicInterleukin-6HumansBiomarkersLimit of DetectionTears

Author keywords

biosensorscarbon nanotubefield effect transistorinterface engineeringpoint-of-care test

Substances

Nanotubes, CarbonBiomarkersInterleukin-6

Authors and institutions

  • Hunan Institute of Advanced Sensing and Information Technology, Xiangtan University, Xiangtan, Hunan 411105, China.
  • Key Laboratory for the Physics and Chemistry of Nanodevices and Center for Carbon-Based Electronics, School of Electronics, Peking University, Beijing 100871, China.
  • Department of Ophthalmology, Beijing Chaoyang Hospital, Capital Medical University, Beijing 100020, China.

ORCID profiles: Mengmeng Xiao

Funding

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Xiangtan University

Cite

APA

Zhu, Z., Li, T., Liu, H. Y., Luan, F. X., Pang, Z., Zhang, Y., He, J., Chen, J., Tao, Y., & Xiao, M. (2025). Interface Cleaning Strategy of Carbon Nanotube Field-Effect Transistor Biosensors for Ultrasensitive Detection of Ophthalmic Biomarkers. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5c04579

Vancouver

Zhu Z, Li T, Liu HY, Luan FX, Pang Z, Zhang Y, et al. Interface Cleaning Strategy of Carbon Nanotube Field-Effect Transistor Biosensors for Ultrasensitive Detection of Ophthalmic Biomarkers. ACS Applied Materials & Interfaces. 2025. doi:10.1021/acsami.5c04579

BibTeX
@article{Zhu2025,
  author = {Zhu, Zhibiao and Li, Tingxian and Liu, Hai-Yang and Luan, Fu-Xiao and Pang, Zitan and Zhang, Yang and He, Jianping and Chen, Jia and Tao, Yong and Xiao, Mengmeng},
  title = {Interface Cleaning Strategy of Carbon Nanotube Field-Effect Transistor Biosensors for Ultrasensitive Detection of Ophthalmic Biomarkers},
  journal = {ACS Applied Materials & Interfaces},
  year = {2025},
  doi = {10.1021/acsami.5c04579}
}
Start for free →