EUVIMEDEUVIMED entdecken
Crossref

Amyloid-like nanofilm-decorated antifouling field effect transistor biosensor array for enhancing Alzheimer's disease diagnosis

Xin Wang, Jiajun Tong, Mengxin Wang, Bin Du, Hongqiang Wang, Hui Liu, Xiaohai Yang, Rong Mu, Kemin Wang, Xiaofeng Liu, Qing Wang

Biosensors and Bioelectronics · 2026-11 · 312 · 119030

DOI: 10.1016/j.bios.2026.119030 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Xin Wang und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engi…. Hauptthemen laut MEDLINE: Biosensing Techniques, Alzheimer Disease, tau Proteins, Serum Albumin, Bovine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Hunan Provincial Natural Science Foundation, National Natural Science Foundation of China, Ministry of Ecology and Environment, The People’s Republic of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Alzheimer's disease (AD) is a common neurodegenerative disorder. Compared to the limited specificity of single-biomarker detection, the combined detection of multiple biomarkers can significantly improve the accuracy of AD diagnosis. In this study, a field-effect transistor (FET) biosensor array integrating four independently functionalized regions was fabricated by modifying carbon nanotube (CNT) surfaces with amyloid bovine serum albumin (AL-BSA) nanofilm as an antifouling layer, enabling the simultaneous detection of multiple tau proteins. The proposed FET biosensor exhibited excellent anti-fouling performance while maintaining high sensitivity, with detection limits as low as 3.3 fg/mL, 0.17 fg/mL, 0.02 fg/mL, and 2.5 fg/mL for p-tau181, p-tau217, p-tau231, and t-tau, respectively. Evaluation of 35 clinical serum samples indicated that p-tau181 outperformed the other three tau proteins as an AD diagnostic biomarker. By further incorporating a support vector machine (SVM)-based machine learning algorithm and employing multi-biomarker co-detection, the accuracy of AD diagnosis can be improved to nearly 100%. This study provides a novel strategy for array FET biosensors with high clinical application potential for the precise detection of AD.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAlzheimer Diseasetau ProteinsSerum Albumin, BovineHumansNanotubes, CarbonTransistors, ElectronicBiomarkersAnimalsEquipment DesignCattleLimit of DetectionSupport Vector Machine

Stichwörter der Autor:innen

Amyloid-like BSABiosensor arrayField-effect-transistorMachine-learningMultiple tau proteins

Substanzen

tau ProteinsSerum Albumin, BovineNanotubes, CarbonBiomarkers

Autor:innen und Institutionen

  • State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha, 410082, China.
  • Hunan Institute of Advanced Sensing and Information Technology, Hunan Provincial Key Laboratory of Smart Carbon Materials and Advanced Sensing, Xiangtan University, Hunan, 411105, China.
  • Department of Experimental Psychology, University of Oxford, Oxford, OX1 3EL, United Kingdom.
  • Hunan Institute of Advanced Sensing and Information Technology, Hunan Provincial Key Laboratory of Smart Carbon Materials and Advanced Sensing, Xiangtan University, Hunan, 411105, China. Electronic address: lxf0301@xtu.…
  • State Key Laboratory of Chemo and Biosensing, College of Chemistry and Chemical Engineering, Key Laboratory for Bio-Nanotechnology and Molecular Engineering of Hunan Province, Hunan University, Changsha, 410082, China.…

Förderung

  • Hunan Provincial Natural Science Foundation
  • National Natural Science Foundation of China
  • Ministry of Ecology and Environment, The People’s Republic of China

Zitieren

APA

Wang, X., Tong, J., Wang, M., Du, B., Wang, H., Liu, H., Yang, X., Mu, R., Wang, K., Liu, X., & Wang, Q. (2026). Amyloid-like nanofilm-decorated antifouling field effect transistor biosensor array for enhancing Alzheimer's disease diagnosis. Biosensors and Bioelectronics, 312, 119030. https://doi.org/10.1016/j.bios.2026.119030

Vancouver

Wang X, Tong J, Wang M, Du B, Wang H, Liu H, et al. Amyloid-like nanofilm-decorated antifouling field effect transistor biosensor array for enhancing Alzheimer's disease diagnosis. Biosensors and Bioelectronics. 2026;312:119030. doi:10.1016/j.bios.2026.119030

BibTeX
@article{Wang2026,
  author = {Wang, Xin and Tong, Jiajun and Wang, Mengxin and Du, Bin and Wang, Hongqiang and Liu, Hui and Yang, Xiaohai and Mu, Rong and Wang, Kemin and Liu, Xiaofeng and Wang, Qing},
  title = {Amyloid-like nanofilm-decorated antifouling field effect transistor biosensor array for enhancing Alzheimer's disease diagnosis},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {312},
  pages = {119030},
  doi = {10.1016/j.bios.2026.119030}
}
Kostenlos starten →