Journal article in ACS Applied Materials & Interfaces, published online on 2025-01-22. Written by Rose Mery Bakestani and 5 co-authors. Institution: Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States. Major MEDLINE topics: Aptamers, Nucleotide, Biosensing Techniques, Electrochemical Techniques, Carboxylic Acids. Cited 22 times so far (Crossref); 52 references. The full text is freely available (open access, CC BY 4.0). Funded by: NIDDK NIH HHS, NIBIB NIH HHS, National Institute of Diabetes and Digestive and Kidney Diseases.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Electrochemical aptamer-based (EAB) sensors are a molecular measurement platform that enables the continuous, real-time measurement of a wide range of drugs and biomarkers in situ in the living body. EAB sensors are fabricated by depositing a thiol-modified, target-binding aptamer on the surface of a gold electrode, followed by backfilling with an alkanethiol to form a self-assembled monolayer. And while the majority of previously described EAB sensors have employed hydroxyl-terminated monolayers, a handful of studies have shown that altering the monolayer headgroup can strongly affect sensor performance. Here, using 4 different EAB sensors, we show that the mixed monolayers composed of mixtures of 6-carbon hydroxyl-terminated thiols and varying amounts of either 6- or 8-carbon, carboxylate-terminated thiols lead to improved EAB sensor performance. Specifically, the use of such mixed monolayers enhances the signal gain (the relative change in the signal seen upon target addition) for all tested sensors, often by several fold, both in buffer and whole blood at room temperature or physiological temperatures. Moreover, these improvements in gain are achieved without significant changes in the aptamer affinity or the stability of the resulting sensors. In addition to proving a ready means of improving EAB sensor performance, these results suggest that exploration of the chemistry of the electrode surface employed in such sensors could prove to be a fruitful means of advancing this unique in vivo sensing technology.

Subjects

MeSH terms (MEDLINE)

Aptamers, NucleotideBiosensing TechniquesElectrochemical TechniquesCarboxylic AcidsElectrodesGoldSulfhydryl CompoundsSurface PropertiesHumans

Author keywords

electrochemical aptamer-based sensorselectrochemical biosensingself-assembled monolayersquare-wave voltammetrysurface chemistry

Substances

Aptamers, NucleotideGoldSulfhydryl CompoundsCarboxylic Acids

Authors and institutions

  • Department of Chemistry and Biochemistry, University of California Santa Barbara, Santa Barbara, California 93106, United States.
  • Department of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, 28040 Madrid, Spain.
  • Department of Psychological and Brain Sciences, University of California Santa Barbara, Santa Barbara, California 93106, United States.
  • Biological Engineering Graduate Program, University of California Santa Barbara, Santa Barbara, California 93106, United States.

ORCID profiles: Rose Mery Bakestani, Bettina Glahn-Martínez, Kevin W Plaxco, Ruben W Kolkman

Funding

  • NIDDK NIH HHS
  • NIBIB NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Institute of Biomedical Imaging and Bioengineering
  • Nederlandse Organisatie voor Wetenschappelijk Onderzoek

Cite

APA

Bakestani, R. M., Wu, Y., Glahn-Martínez, B., Kippin, T. E., Plaxco, K. W., & Kolkman, R. W. (2025). Carboxylate-Terminated Electrode Surfaces Improve the Performance of Electrochemical Aptamer-Based Sensors. ACS Applied Materials & Interfaces, 17(5), 8706-8714. https://doi.org/10.1021/acsami.4c21790

Vancouver

Bakestani RM, Wu Y, Glahn-Martínez B, Kippin TE, Plaxco KW, Kolkman RW. Carboxylate-Terminated Electrode Surfaces Improve the Performance of Electrochemical Aptamer-Based Sensors. ACS Applied Materials & Interfaces. 2025;17(5):8706-8714. doi:10.1021/acsami.4c21790

BibTeX
@article{Bakestani2025,
  author = {Bakestani, Rose Mery and Wu, Yuyang and Glahn-Martínez, Bettina and Kippin, Tod E and Plaxco, Kevin W and Kolkman, Ruben W},
  title = {Carboxylate-Terminated Electrode Surfaces Improve the Performance of Electrochemical Aptamer-Based Sensors},
  journal = {ACS Applied Materials & Interfaces},
  year = {2025},
  volume = {17},
  number = {5},
  pages = {8706--8714},
  doi = {10.1021/acsami.4c21790}
}
Start for free →