EUVIMEDEUVIMED entdecken
Crossref

Utilization of Spontaneous Alkyne–Gold Self-Assembly Chemistry as an Alternative Method for Fabricating Electrochemical Aptamer-Based Sensors

Lars Alexander Olivan, Kaitlyn Hand, Ryan J White iD

Langmuir · 2024

DOI: 10.1021/acs.langmuir.4c00972 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Langmuir, 2024. Verfasst von Lars Alexander Olivan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221-0171, United States. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, Gold, Biosensing Techniques, Electrochemical Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: American Chemical Society, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical aptamer-based (E-AB) sensors are a promising class of biosensors which use structure-switching redox-labeled oligonucleotides (aptamers) codeposited with passivating alkanethiol monolayers on electrode surfaces to specifically bind and detect target analytes. Signaling in E-AB sensors is an outcome of aptamer conformational changes upon target binding, with the sequence of the aptamer imparting specificity toward the analyte of interest. The change in conformation translates to a change in electron transfer between the redox label attached to the aptamer and the underlying electrode and is related to analyte concentration, allowing specific electrochemical detection of nonelectroactive analytes. E-AB sensor measurements are reagentless with time resolutions of seconds or less and may be miniaturized into the submicron range. Traditionally these sensors are fabricated using thiol-on-gold chemistry. Here we present an alternate immobilization chemistry, gold-alkyne binding, which results in an increase in sensor lifetimes under ideal conditions by up to ∼100%. We find that gold-alkyne binding is spontaneous and supports efficient E-AB sensor signaling with analytical performance characteristics similar to those of thiol generated monolayers. The surface modification differs from gold-thiol binding only in the time and aptamer concentration required to achieve similar aptamer surface coverages. In addition, alkynated aptamers differ from their thiolated analogues only by their chemical handle for surface attachment, so any existing aptamers can be easily adapted to utilize this attachment strategy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aptamers, NucleotideGoldBiosensing TechniquesElectrochemical TechniquesAlkynesElectrodesSulfhydryl Compounds

Substanzen

Aptamers, NucleotideGoldAlkynesSulfhydryl Compounds

Autor:innen und Institutionen

  • Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221-0171, United States.
  • Department of Electrical and Computer Engineering, University of Cincinnati, Cincinnati, Ohio 45221, United States.

ORCID-Profile: Ryan J White

Förderung

  • American Chemical Society
  • National Institutes of Health

Zitieren

APA

Olivan, L. A., Hand, K., & White, R. J. (2024). Utilization of Spontaneous Alkyne–Gold Self-Assembly Chemistry as an Alternative Method for Fabricating Electrochemical Aptamer-Based Sensors. Langmuir. https://doi.org/10.1021/acs.langmuir.4c00972

Vancouver

Olivan LA, Hand K, White RJ. Utilization of Spontaneous Alkyne–Gold Self-Assembly Chemistry as an Alternative Method for Fabricating Electrochemical Aptamer-Based Sensors. Langmuir. 2024. doi:10.1021/acs.langmuir.4c00972

BibTeX
@article{Olivan2024,
  author = {Olivan, Lars Alexander and Hand, Kaitlyn and White, Ryan J},
  title = {Utilization of Spontaneous Alkyne–Gold Self-Assembly Chemistry as an Alternative Method for Fabricating Electrochemical Aptamer-Based Sensors},
  journal = {Langmuir},
  year = {2024},
  doi = {10.1021/acs.langmuir.4c00972}
}
Kostenlos starten →