EUVIMEDOpdag EUVIMED
Open access

Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2

Heshmat Asgharian iD, Vinay Kammarchedu iD, Pouya Soltan Khamsi iD, Caroline Brustoloni, Aida Ebrahimi iD

ACS Applied Materials & Interfaces · 2024-11-20 · 16 (46) · 63142-63154

DOI: 10.1021/acsami.4c11393 ↗

At a glance

Journal article in ACS Applied Materials & Interfaces, published online on 2024-10-29. Written by Heshmat Asgharian and 4 co-authors. Institution: Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States. Major MEDLINE topics: Graphite, SARS-CoV-2, Ascorbic Acid, Biosensing Techniques. Cited 13 times so far (Crossref); 67 references. The full text is freely available in PubMed Central. Funded by: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering, Division of Engineering Education and Centers.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Despite the clinical data showing the importance of ascorbic acid (AA or vitamin C) in managing viral respiratory infections, biosensors for their simultaneous detection are lacking. To address this need, we developed a portable and wireless device for simultaneous detection of AA and SARS-CoV-2 virus by integrating commercial transistors with printed laser-induced graphene (LIG) as the extended gate. We studied the effect of laser printing pass number and showed that with two laser printing passes (2-pass LIG), the sensor sensitivity and limit of detection (LOD) for AA improved by a factor of 1.6 and 12.8, respectively. Using complementary characterization methods, we attribute the improved response to a balanced interplay of crystallinity, defect density, surface area, surface roughness, pore density and diameter, and mechanical integrity/stability. These factors enhance analyte transport, reduce noise/variability, and ensure consistent sensor performance, making 2-pass LIG the most effective material in this work. Our sensors exhibit promising performance for detecting AA with a selective response in the presence of common salivary interfering molecules, with sensitivity and LOD of 73.67 mV/dec and 54.04 nM in 1× phosphate buffered saline and 81.05 mV/dec and 78.34 nM in artificial saliva, respectively. We also showed that functionalization of the 2-pass LIG gate with S-protein antibody enables the detection of SARS-CoV-2 protein antigens with an ultralow LOD of 52 zg/mL─an improvement of more than 10-fold compared to 1-pass LIG─and 4 particles/mL for virion mimics with a selective response against influenza virus and multiple human coronavirus strains. With low signal drift/hysteresis and wireless capabilities, the developed device holds great potential for improving at-home monitoring and clinical decision-making.

Subjects

MeSH terms (MEDLINE)

GraphiteSARS-CoV-2Ascorbic AcidBiosensing TechniquesCOVID-19Transistors, ElectronicLasersHumansLimit of DetectionElectrodesElectrochemical Techniques

Author keywords

SARS-CoV-2 virusascorbic acidextended gate field effect transistorlaser-induced graphenewireless

Substances

GraphiteAscorbic Acid

Authors and institutions

  • Department of Electrical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.
  • Materials Research Institute, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.
  • Center for Atomically Thin Multifunctional Coatings, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.
  • Department of Biomedical Engineering, The Pennsylvania State University, University Park, Pennsylvania 16802, United States.

ORCID profiles: Heshmat Asgharian, Vinay Kammarchedu, Pouya Soltan Khamsi, Aida Ebrahimi

Funding

  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • Division of Engineering Education and Centers
  • Division of Electrical, Communications and Cyber Systems

Cite

APA

Asgharian, H., Kammarchedu, V., Soltan Khamsi, P., Brustoloni, C., & Ebrahimi, A. (2024). Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2. ACS Applied Materials & Interfaces, 16(46), 63142-63154. https://doi.org/10.1021/acsami.4c11393

Vancouver

Asgharian H, Kammarchedu V, Soltan Khamsi P, Brustoloni C, Ebrahimi A. Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2. ACS Applied Materials & Interfaces. 2024;16(46):63142-63154. doi:10.1021/acsami.4c11393

BibTeX
@article{Asgharian2024,
  author = {Asgharian, Heshmat and Kammarchedu, Vinay and Soltan Khamsi, Pouya and Brustoloni, Caroline and Ebrahimi, Aida},
  title = {Multi-Electrode Extended Gate Field Effect Transistors Based on Laser-Induced Graphene for the Detection of Vitamin C and SARS-CoV-2},
  journal = {ACS Applied Materials & Interfaces},
  year = {2024},
  volume = {16},
  number = {46},
  pages = {63142--63154},
  doi = {10.1021/acsami.4c11393}
}
Start for free →