Micromotor-assisted graphene field-effect transistor for label-free and ultrasensitive detection of SARS-CoV-2 in complex matrices
Microchimica Acta · 2026-07 · 193 (7)
DOI: 10.1007/s00604-026-08190-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 15.06.2026. Verfasst von Yushuang Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Stora…. Hauptthemen laut MEDLINE: SARS-CoV-2, Graphite, Transistors, Electronic, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Outbreaks of infectious diseases pose a major challenge to public health and social development, creating an urgent need for rapid, sensitive, and field-deployable diagnostic platforms. We developed a label-free sensing strategy for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by integrating antibody-functionalized Fe3O4@TiO2@MnO2 magnetic micromotors with a graphene field-effect transistor (GFET). The micromotors exhibited self-propulsion in H2O2 solution due to catalytic oxygen generation, which enhanced target capture and enrichment efficiency. After magnetic separation, the collected micromotor-target complexes were directly analyzed by GFET for quantitative detection. Under optimized conditions, the platform showed a wide linear response and achieved an ultralow limit of detection of ag/mL in PBS. The sensing system also maintained reliable analytical performance in complex matrices, with detection limits of 37.5 ag/mL in human serum and 19.1 ag/mL in soil solution. In addition, the platform exhibited excellent reproducibility and favorable reusability. These results demonstrate that the proposed micromotor-assisted GFET platform provides a sensitive and robust approach for SARS-CoV-2 detection and holds considerable promise for on-site determination of infectious pathogens in complex real-sample environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Inner Mongolia Key Laboratory of Solid State Chemistry for Battery, Inner Mongolia Engineering Research Center of Lithium-Sulfur Battery Energy Storage, College of Chemistry and Materials Science, Inner Mongolia Minzu U…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Liu, Y., Zhou, G., Hu, S., Hai, W., Du, C., & Xing, L. (2026). Micromotor-assisted graphene field-effect transistor for label-free and ultrasensitive detection of SARS-CoV-2 in complex matrices. Microchimica Acta, 193(7). https://doi.org/10.1007/s00604-026-08190-5
Vancouver
Liu Y, Zhou G, Hu S, Hai W, Du C, Xing L. Micromotor-assisted graphene field-effect transistor for label-free and ultrasensitive detection of SARS-CoV-2 in complex matrices. Microchimica Acta. 2026;193(7). doi:10.1007/s00604-026-08190-5
BibTeX
@article{Liu2026,
author = {Liu, Yushuang and Zhou, Guiqi and Hu, Shuang and Hai, Wenfeng and Du, Chunyu and Xing, Lin},
title = {Micromotor-assisted graphene field-effect transistor for label-free and ultrasensitive detection of SARS-CoV-2 in complex matrices},
journal = {Microchimica Acta},
year = {2026},
volume = {193},
number = {7},
doi = {10.1007/s00604-026-08190-5}
}
EUVIMED