Stability Enhancement by Hydrophobic Anchoring and a Cross-Linked Structure of a Phospholipid Copolymer Film for Medical Devices
ACS Applied Materials & Interfaces · 2024
DOI: 10.1021/acsami.4c07752 ↗At a glance
Journal article in ACS Applied Materials & Interfaces, 2024. Written by Kazuto Uchida and 11 co-authors. Institution: Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan. Major MEDLINE topics: Hydrophobic and Hydrophilic Interactions. Cited 8 times so far (Crossref); 53 references. Funded by: Japan Agency for Medical Research and Development, Japan Society for the Promotion of Science.
Abstract (original language)
Surface modification using zwitterionic 2-methacryloyloxyethylphosphorylcholine (MPC) polymers is one of the most reasonable ways to prepare medical devices that can suppress undesired biological reactions such as blood coagulation. Usable MPC polymers are hydrophilic and water soluble, and their surface modification strategy involves exploiting the copolymer structures by adding physical or chemical bonding moieties. In this study, we developed copolymers composed of MPC, hydrophobic anchoring moiety, and chemical cross-linking unit to clarify the role of hydrophobic interactions in achieving biocompatible and long-term stable coatings. The four kinds of MPC copolymers with cross-linking units, such as 3-methacryloxypropyl trimethoxysilane (MPTMSi), and four different hydrophobic anchoring moieties, such as 3-(methacryloyloxy)propyltris(trimethylsiloxy)silane (MPTSSi) named as PMMMSi, n-butyl methacrylate (BMA) as PMBSi, 2-ethylhexyl methacrylate (EHMA) as PMESi, and lauryl methacrylate as PMLSi, were synthesized and coated on polydimethylsiloxane, polypropylene (PP), and polymethyl pentene. These copolymers were uniformly coated on the substrate materials PP and poly(methyl pentene) (PMP), to achieve hydrophilic and electrically neutral coatings. The results of the antibiofouling test showed that PMBSi repelled the adsorption of fluorescence-labeled bovine serum albumin the most, whereas PMLSi repelled it the least. Notably, all four copolymers suppressed platelet adhesion similarly. The variations in protein adsorption quantities among the four copolymer coatings were attributed to their distinct swelling behaviors in aqueous environments. Further investigations, including 3D scanning force microscopy and neutron reflectivity measurements, revealed that the PMLSi coating exhibited a higher water intake under aqueous conditions in comparison to the other coatings. Consequently, all copolymer coatings effectively prevented the invasion of platelets but the proteins penetrated the PMLSi network. Subsequently, the dynamic stability required to induce shear stress was evaluated using a circulation system. The results demonstrated that the PMMMSi and PMLSi coatings on PMP and PP exhibited exceptional platelet repellency and maintained high stability during circulation. This study highlights the potential of hydrophobic moieties to improve hemocompatibility and stability, offering potential applications in medical devices.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Bioengineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan.
- Department of Clinical Engineering, Tokyo Women's Medical University, 8-1, Kawada-cho, Shinjuku-ku, Tokyo 162-8666, Japan.
- Institute of Materials Structure Science, High Energy Accelerator Research Organization, 203-1, Shirakata, Tokai, Ibaraki 319-1106, Japan.
- Materials and Life Science Division, J-PARC Center, Japan Atomic Energy Agency, 2-4, Shirakata, Tokai, Ibaraki 319-1195, Japan.
- Division of Electrical Engineering and Computer Science, Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
- WPI Nano Life Science Institute (WPI-NanoLSI), Kanazawa University, Kakuma-machi, Kanazawa 920-1192, Japan.
ORCID profiles: Tsukuru Masuda, Hiroyuki Aoki, Kazuki Miyata, Takeshi Fukuma, Madoka Takai
Funding
- Japan Agency for Medical Research and Development
- Japan Society for the Promotion of Science
Cite
APA
Uchida, K., Masuda, T., Hara, S., Matsuo, Y., Liu, Y., Aoki, H., Asano, Y., Miyata, K., Fukuma, T., Ono, T., Isoyama, T., & Takai, M. (2024). Stability Enhancement by Hydrophobic Anchoring and a Cross-Linked Structure of a Phospholipid Copolymer Film for Medical Devices. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.4c07752
Vancouver
Uchida K, Masuda T, Hara S, Matsuo Y, Liu Y, Aoki H, et al. Stability Enhancement by Hydrophobic Anchoring and a Cross-Linked Structure of a Phospholipid Copolymer Film for Medical Devices. ACS Applied Materials & Interfaces. 2024. doi:10.1021/acsami.4c07752
BibTeX
@article{Uchida2024,
author = {Uchida, Kazuto and Masuda, Tsukuru and Hara, Shintaro and Matsuo, Youichi and Liu, Yuwei and Aoki, Hiroyuki and Asano, Yoshihiko and Miyata, Kazuki and Fukuma, Takeshi and Ono, Toshiya and Isoyama, Takashi and Takai, Madoka},
title = {Stability Enhancement by Hydrophobic Anchoring and a Cross-Linked Structure of a Phospholipid Copolymer Film for Medical Devices},
journal = {ACS Applied Materials & Interfaces},
year = {2024},
doi = {10.1021/acsami.4c07752}
}
EUVIMED