EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydrophobic 2-methacryloyloxyethyl phosphorylcholine polymer inhibits peri-implantitis-causing bacterial adhesion on titanium materials

Minato Akizuki, Keiji Murakami, Kazumitsu Sekine, Akikazu Murakami iD, Koh Kobayashi, Masaru Matsuda, Haruka Matsumoto, Eiji Harata, Kenichi Hamada, Raras Ajeng Enggardipta, Hideki Fujii, Hiromichi Yumoto iD

Journal of Applied Microbiology · 2025

DOI: 10.1093/jambio/lxaf033 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Microbiology, 2025. Verfasst von Minato Akizuki und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Periodontology and Endodontology, Graduate School of Biomedical Sciences, Tokushima University, Tokushima 770-8504, Japan. Hauptthemen laut MEDLINE: Bacterial Adhesion, Phosphorylcholine, Titanium, Methacrylates. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS, NOF.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To prevent peri-implantitis, we investigated the adhesion of periodontopathogenic bacteria to titanium surfaces using a hydrophobic 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer to inhibit adhesion. Method and results We immersed titanium plates (TiPs) coated with a hydrophobic MPC polymer in a bacterial suspension for 30 min or 24 h and measured the number of adherent bacteria. Bacteria adhering to the TiPs were observed using scanning electron microscopy (SEM). Furthermore, mimicking an oral cavity, TiPs coated with MPC polymer and saliva, were immersed in bacterial suspensions of Porphyromonas gingivalis, Fusobacterium nucleatum, and Streptococcus mutans for 24 h, and adenosine triphosphate in the adherent bacteria was measured. Bacterial adhesion was significantly inhibited on MPC polymer-coated TiPs after 30 min and 24 h. SEM results showed a similar trend. Bacterial adhesion was significantly inhibited on MPC polymer-treated TiPs in the presence of saliva, both before and after MPC treatment. Furthermore, their effectiveness was maintained when the MPC polymer-treated TiPs were stored in saline for 1 week.

Conclusions

Hydrophobic MPC polymer coating on TiP surface inhibited bacterial adhesion, indicating that it may be effective in preventing peri-implantitis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bacterial AdhesionPhosphorylcholineTitaniumMethacrylatesPeri-ImplantitisStreptococcus mutansPorphyromonas gingivalisHydrophobic and Hydrophilic InteractionsFusobacterium nucleatumHumansMicroscopy, Electron, ScanningSalivaPolymersCoated Materials, BiocompatibleDental ImplantsSurface Properties

Stichwörter der Autor:innen

bacterial adhesionhydrophobic MPC polymerperi-implantitistitanium plate

Substanzen

PhosphorylcholineTitanium2-methacryloyloxyethyl phosphorylcholineMethacrylatesPolymersCoated Materials, BiocompatibleDental Implants

Autor:innen und Institutionen

  • Department of Periodontology and Endodontology, Graduate School of Biomedical Sciences, Tokushima University, Tokushima 770-8504, Japan.
  • Department of Clinical Nutrition, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, Kurashiki 701-0193, Japan.
  • Department of Biomaterials and Bioengineering, Graduate School of Biomedical Sciences, Tokushima University, Tokushima 770-8504, Japan.
  • Department of Oral Microbiology, Graduate School of Biomedical Sciences, Tokushima University, Tokushima 770-8504, Japan.
  • Life Science Division, NOF CORPORATION, 20-3 Ebisu 4-chome, Shibuya-ku, Tokyo 150-6012, Japan.
  • Department of Biology, Keio University School of Medicine, Yokohama 223-8521, Japan.

ORCID-Profile: Akikazu Murakami, Hiromichi Yumoto

Förderung

  • JSPS
  • NOF

Zitieren

APA

Akizuki, M., Murakami, K., Sekine, K., Murakami, A., Kobayashi, K., Matsuda, M., Matsumoto, H., Harata, E., Hamada, K., Enggardipta, R. A., Fujii, H., & Yumoto, H. (2025). Hydrophobic 2-methacryloyloxyethyl phosphorylcholine polymer inhibits peri-implantitis-causing bacterial adhesion on titanium materials. Journal of Applied Microbiology. https://doi.org/10.1093/jambio/lxaf033

Vancouver

Akizuki M, Murakami K, Sekine K, Murakami A, Kobayashi K, Matsuda M, et al. Hydrophobic 2-methacryloyloxyethyl phosphorylcholine polymer inhibits peri-implantitis-causing bacterial adhesion on titanium materials. Journal of Applied Microbiology. 2025. doi:10.1093/jambio/lxaf033

BibTeX
@article{Akizuki2025,
  author = {Akizuki, Minato and Murakami, Keiji and Sekine, Kazumitsu and Murakami, Akikazu and Kobayashi, Koh and Matsuda, Masaru and Matsumoto, Haruka and Harata, Eiji and Hamada, Kenichi and Enggardipta, Raras Ajeng and Fujii, Hideki and Yumoto, Hiromichi},
  title = {Hydrophobic 2-methacryloyloxyethyl phosphorylcholine polymer inhibits peri-implantitis-causing bacterial adhesion on titanium materials},
  journal = {Journal of Applied Microbiology},
  year = {2025},
  doi = {10.1093/jambio/lxaf033}
}
Kostenlos starten →