EUVIMEDEUVIMED entdecken
Crossref

Fluorescence Turn-on Detection of Perfluorooctanoic Acid (PFOA) by Perylene Diimide-Based Metal–Organic Framework

Rana Dalapati, Matthew Hunter, Mostakim Sk, Xiaomei Yang, Ling Zang iD

ACS Applied Materials & Interfaces · 26.06.2024 · 16 (25) · 32344-32356

DOI: 10.1021/acsami.4c03389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Applied Materials & Interfaces, online erschienen am 08.05.2024. Verfasst von Rana Dalapati und 4 weiteren Autor:innen. Beteiligte Einrichtung: Nano Institute of Utah, and Department of Materials Science and Engineering, University of Utah, Salt Lake City, Utah 84112, United States. Die Arbeit wurde bisher 106-mal zitiert (Crossref) und nennt 96 Literaturangaben. Gefördert von: Gentex Corporation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel, water-stable, perylene diimide (PDI) based metal-organic framework (MOF), namely, U-1, has been synthesized for selective and sensitive detection of perfluorooctanoic acid (PFOA) in mixed aqueous solutions. The MOF shows highly selective fluorescence turn-on detection via the formation of a PFOA-MOF complex. This PFOA-MOF complex formation was confirmed by various spectroscopic techniques. The detection limit of the MOF for PFOA was found to be 1.68 μM in an aqueous suspension. Upon coating onto cellulose paper, the MOF demonstrated a significantly lower detection limit, down to 3.1 nM, which is mainly due to the concentrative effect of solid phase extraction (SPE). This detection limit is lower than the fluorescence sensors based on MOFs previously reported for PFAS detection. The MOF sensor is regenerable and capable of detecting PFOA in drinking and tap water samples. The PDI-MOF-based sensor reported herein represents a novel approach, relying on fluorescence turn-on response, that has not yet been thoroughly investigated for detecting per- and polyfluoroalkyl substances (PFAS) until now.

Schlagwörter

Stichwörter der Autor:innen

Fluorescence turn-onFluorescent sensorMetal−organic framework (MOF)Perfluorooctanoic acid (PFOA)Perylene diimide (PDI)

Autor:innen und Institutionen

  • Nano Institute of Utah, and Department of Materials Science and Engineering, University of Utah, Salt Lake City, Utah 84112, United States.
  • Lab of Soft Interfaces, Department of Metallurgical Engineering and Materials Science, Indian Institute of Technology Bombay, Mumbai 400076, India.

ORCID-Profile: Ling Zang

Förderung

  • Gentex Corporation

Zitieren

APA

Dalapati, R., Hunter, M., Sk, M., Yang, X., & Zang, L. (2024). Fluorescence Turn-on Detection of Perfluorooctanoic Acid (PFOA) by Perylene Diimide-Based Metal–Organic Framework. ACS Applied Materials & Interfaces, 16(25), 32344-32356. https://doi.org/10.1021/acsami.4c03389

Vancouver

Dalapati R, Hunter M, Sk M, Yang X, Zang L. Fluorescence Turn-on Detection of Perfluorooctanoic Acid (PFOA) by Perylene Diimide-Based Metal–Organic Framework. ACS Applied Materials & Interfaces. 2024;16(25):32344-32356. doi:10.1021/acsami.4c03389

BibTeX
@article{Dalapati2024,
  author = {Dalapati, Rana and Hunter, Matthew and Sk, Mostakim and Yang, Xiaomei and Zang, Ling},
  title = {Fluorescence Turn-on Detection of Perfluorooctanoic Acid (PFOA) by Perylene Diimide-Based Metal–Organic Framework},
  journal = {ACS Applied Materials & Interfaces},
  year = {2024},
  volume = {16},
  number = {25},
  pages = {32344--32356},
  doi = {10.1021/acsami.4c03389}
}