Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-08. Verfasst von Yuanyuan Yang und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science & Engineering, Tongji University, Shanghai Institute o…. Hauptthemen laut MEDLINE: Smartphone, Metal-Organic Frameworks, Caprylates, Fluorescent Dyes. Die Arbeit wurde bisher 103-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Perfluorooctanoic acid (PFOA) poses a threat to the environment and human health due to its persistence, bioaccumulation, and reproductive toxicity. Herein, a lanthanide metal-organic framework (Ln-MOF)-based surface molecularly imprinted polymers (SMIPs) ratiometric fluorescence probe (Eu/Tb-MOF@MIPs) and a smartphone-assisted portable device were developed for the detection of PFOA with high selectivity in real water samples. The integration of Eu/Tb MOFs as carriers not only had highly stable multiple emission signals but also prevented deformation of the imprinting cavity of MIPs. Meanwhile, the MIPs layer preserved the fluorescence of Ln-MOF and provided selective cavities for improved specificity. Molecular dynamics (MD) was employed to simulate the polymerization process of MIPs, revealing that the formation of multiple recognition sites was attributed to the establishment of hydrogen bonds between functional monomers and templates. The probe showed a good linear relationship with PFOA concentration in the range of 0.02-2.8 μM, by giving the limit of detection (LOD) of 0.98 nM. Additionally, The red-green-blue (RGB) values analysis based on the smartphone-assisted portable device demonstrated a linear relationship of 0.1-2.8 μM PFOA with the LOD of 3.26 nM. The developed probe and portable device sensing platform exhibit substantial potential for on-site detecting PFOA in practical applications and provide a reliable strategy for the intelligent identification of important targets in water environmental samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science & Engineering, Tongji University, Shanghai Institute of Pollution Control and Ecological Security, 1239 Siping Road, Shangha…
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Yang, Y., Liu, X., Mu, B., Meng, S., Mao, S., Tao, W., & Li, Z. (2024). Lanthanide metal-organic framework-based surface molecularly imprinted polymers ratiometric fluorescence probe for visual detection of perfluorooctanoic acid with a smartphone-assisted portable device. Biosensors and Bioelectronics, 257, 116330. https://doi.org/10.1016/j.bios.2024.116330
Vancouver
Yang Y, Liu X, Mu B, Meng S, Mao S, Tao W, et al. Lanthanide metal-organic framework-based surface molecularly imprinted polymers ratiometric fluorescence probe for visual detection of perfluorooctanoic acid with a smartphone-assisted portable device. Biosensors and Bioelectronics. 2024;257:116330. doi:10.1016/j.bios.2024.116330
BibTeX
@article{Yang2024,
author = {Yang, Yuanyuan and Liu, Xiaohui and Mu, Bofang and Meng, Shuang and Mao, Shun and Tao, Wenquan and Li, Zhuo},
title = {Lanthanide metal-organic framework-based surface molecularly imprinted polymers ratiometric fluorescence probe for visual detection of perfluorooctanoic acid with a smartphone-assisted portable device},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {257},
pages = {116330},
doi = {10.1016/j.bios.2024.116330}
}
EUVIMED