Molecularly Imprinted Polymer Biosensor Based on Nitrogen-Doped Electrochemically Exfoliated Graphene/Ti 3 CNT X MXene Nanocomposite for Metabolites Detection
ACS Applied Materials & Interfaces · 2024-05-29 · 16 (21) · 27714-27727
DOI: 10.1021/acsami.4c01973 ↗At a glance
Journal article in ACS Applied Materials & Interfaces, published online on 2024-05-08. Written by Bahareh Babamiri and 7 co-authors. Institution: BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, Albe…. Major MEDLINE topics: Graphite, Biosensing Techniques, Nanocomposites, Nitrogen. Cited 38 times so far (Crossref); 67 references. Funded by: Canadian Institutes of Health Research, Canada Research Chairs, University of Calgary.
Abstract (original language)
Rapid and accurate quantification of metabolites in different bodily fluids is crucial for a precise health evaluation. However, conventional metabolite sensing methods, confined to centralized laboratory settings, suffer from time-consuming processes, complex procedures, and costly instrumentation. Introducing the MXene/nitrogen-doped electrochemically exfoliated graphene (MXene@N-EEG) nanocomposite as a novel biosensing platform in this work addresses the challenges associated with conventional methods, leveraging the concept of molecularly imprinted polymers (MIP) enables the highly sensitive, specific, and reliable detection of metabolites. To validate our biosensing technology, we utilize agmatine as a significant biologically active metabolite. The MIP biosensor incorporates electrodeposited Prussian blue nanoparticles as a redox probe, facilitating the direct electrical signaling of agmatine binding in the polymeric matrix. The MXene@N-EEG nanocomposite, with excellent metal conductivity and a large electroactive specific surface area, effectively stabilizes the electrodeposited Prussian blue nanoparticles. Furthermore, increasing the content of agmatine-imprinted cavities on the electrode enhances the sensitivity of the MIP biosensor. Evaluation of the designed MIP biosensor in buffer solution and plasma samples reveals a wide linear concentration range of 1.0 nM-100.0 μM (R2 = 0.9934) and a detection limit of 0.1 nM. Notably, the developed microfluidic biosensor offers low cost, rapid response time to the target molecule (10 min of sample incubation), good recovery results for detecting agmatine in plasma samples, and acceptable autonomous performance for on-chip detection. Moreover, its high reliability and sensitivity position this MIP-based biosensor as a promising candidate for miniaturized microfluidic devices with the potential for scalable production for point-of-care applications.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- BioMEMS and Bioinspired Microfluidic Laboratory, Department of Biomedical Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada.
- Department of Chemical and Petroleum Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada.
- Department of Mechanical and Manufacturing Engineering, University of Calgary, 2500 University Drive NW, Calgary, Alberta T2N 1N4, Canada.
- Department of Biological Sciences, University of Calgary, 2500 University Drive, NW, Calgary, Alberta T2N 1N4, Canada.
ORCID profiles: Mohsen Hassani, Edward P L Roberts, Amir Sanati Nezhad
Funding
- Canadian Institutes of Health Research
- Canada Research Chairs
- University of Calgary
- Natural Sciences and Engineering Research Council of Canada
- CMC Microsystems
- Mitacs
- Fluidome Inc.
Cite
APA
Babamiri, B., Sadri, R., Farrokhnia, M., Hassani, M., Kaur, M., Roberts, E. P. L., Ashani, M. M., & Sanati Nezhad, A. (2024). Molecularly Imprinted Polymer Biosensor Based on Nitrogen-Doped Electrochemically Exfoliated Graphene/Ti 3 CNT X MXene Nanocomposite for Metabolites Detection. ACS Applied Materials & Interfaces, 16(21), 27714-27727. https://doi.org/10.1021/acsami.4c01973
Vancouver
Babamiri B, Sadri R, Farrokhnia M, Hassani M, Kaur M, Roberts EPL, et al. Molecularly Imprinted Polymer Biosensor Based on Nitrogen-Doped Electrochemically Exfoliated Graphene/Ti 3 CNT X MXene Nanocomposite for Metabolites Detection. ACS Applied Materials & Interfaces. 2024;16(21):27714-27727. doi:10.1021/acsami.4c01973
BibTeX
@article{Babamiri2024,
author = {Babamiri, Bahareh and Sadri, Rad and Farrokhnia, Mohammadreza and Hassani, Mohsen and Kaur, Manpreet and Roberts, Edward P L and Ashani, Mehdi Mohammadi and Sanati Nezhad, Amir},
title = {Molecularly Imprinted Polymer Biosensor Based on Nitrogen-Doped Electrochemically Exfoliated Graphene/Ti 3 CNT X MXene Nanocomposite for Metabolites Detection},
journal = {ACS Applied Materials & Interfaces},
year = {2024},
volume = {16},
number = {21},
pages = {27714--27727},
doi = {10.1021/acsami.4c01973}
}
EUVIMED