Journal article in ACS Applied Materials & Interfaces, published online on 2023-04-19. Written by Disiya Davis and 8 co-authors. Institution: Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India. Cited 32 times so far (Crossref); 69 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Paper-based lightweight, degradable, low-cost, and eco-friendly substrates are extensively used in wearable biosensor applications, albeit to a lesser extent in sensing acetone and other gas-phase analytes. Generally, rigid substrates with heaters have been employed to develop acetone sensors due to the high operating/recovery temperature (typically above 200 °C), limiting the use of papers as substrates in such sensing applications. In this work, we proposed fabricating the paper-based, room-temperature-operatable acetone sensor using ZnO-polyaniline-based acetone-sensing inks by a facile fabrication method. The fabricated paper-based electrodes showed good electrical conductivity (80 S/m) and mechanical stability (∼1000 bending cycles). The acetone sensors showed a sensitivity of 0.02/100 ppm and 0.6/10 μL with an ultrafast response (4 s) and recovery time (15 s) at room temperature. The sensors delivered a broad sensitivity over a physiological range of 260 to >1000 ppm with R2 > 0.98 under atmospheric conditions. Further, the role of the surface, interfacial, microstructure, electrical, and electromechanical properties of the paper-based sensor devices has been correlated with the sensitivity and room-temperature recovery observed in our system. These versatile, green, flexible electronic devices would be ideal for low-cost, highly regenerative, room-/low-temperature-operable wearable sensor applications.

Subjects

Author keywords

acetone sensorsconducting inksflexible electronicspaper electronicswearable sensors

Authors and institutions

  • Centre for Materials for Electronics Technology (C-MET), Shornur Road, Athani, MG Kavu Post, Thrissur 680581, Kerala, India.

ORCID profiles: Arul Kashmir Arulraj

Cite

APA

Davis, D., Narayanan, S. K., Ajeev, A., Nair, J., Jeeji, J., Vijayan, A., Viyyur Kuttyadi, M., Nelliparambil Sathian, A., & Arulraj, A. K. (2023). Flexible Paper-Based Room-Temperature Acetone Sensors with Ultrafast Regeneration. ACS Applied Materials & Interfaces, 15(21), 25734-25743. https://doi.org/10.1021/acsami.2c21712

Vancouver

Davis D, Narayanan SK, Ajeev A, Nair J, Jeeji J, Vijayan A, et al. Flexible Paper-Based Room-Temperature Acetone Sensors with Ultrafast Regeneration. ACS Applied Materials & Interfaces. 2023;15(21):25734-25743. doi:10.1021/acsami.2c21712

BibTeX
@article{Davis2023,
  author = {Davis, Disiya and Narayanan, Swathi Krishna and Ajeev, Arya and Nair, Jayashree and Jeeji, Jithin and Vijayan, Ananthu and Viyyur Kuttyadi, Midhun and Nelliparambil Sathian, Arun and Arulraj, Arul Kashmir},
  title = {Flexible Paper-Based Room-Temperature Acetone Sensors with Ultrafast Regeneration},
  journal = {ACS Applied Materials & Interfaces},
  year = {2023},
  volume = {15},
  number = {21},
  pages = {25734--25743},
  doi = {10.1021/acsami.2c21712}
}
Start for free →