EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Magnetic Detection of Neural Activity by Nanocoil Transducers

Ilhan Bok iD, Jack Phillips, Tianxiang Zhu, Jennifer Lu, Elizabeth Detienne, Eduardo Andrade Lima, Benjamin P Weiss, Alan Jasanoff iD, Aviad Hai iD

Nano Letters · 2024

DOI: 10.1021/acs.nanolett.4c02784 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nano Letters, 2024. Verfasst von Ilhan Bok und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States. Hauptthemen laut MEDLINE: Neurons. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NINDS NIH HHS, NIBIB NIH HHS, NIDA NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrophysiological recordings from brain cells are performed routinely using implanted electrodes, but they traditionally require a wired connection to the outside of the brain. A completely passive, wireless device that does not require on-board power for active transmission but that still facilitates remote detection could open the door for mass-scale direct recording of action potentials and transform the way we acquire brain signals. We present a nanofabricated coil that forms a neuroelectromagnetic junction, yielding a highly enhanced magnetic field transduction of electrophysiology. We show that this micrometer-scale device enables remote magnetic detection of neuronal fields from the center of the coil using room temperature superconducting quantum interference device (SQUID) microscopy. Further, time-locked stimulation in conjunction with magnetometry demonstrates thresholding behavior that affirms the viability of the technology for detection with no requirement for wires or on-board power. This strategy may permit unprecedented detection of electrophysiology using magnetoencephalography and magnetic resonance imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeuronsAction PotentialsBrainTransducersMagnetoencephalographyMagnetic Resonance ImagingAnimalsEquipment DesignNanotechnology

Stichwörter der Autor:innen

ElectrophysiologyMagnetic Resonance ImagingMagnetoencephalographyNanocoilsSQUIDWireless

Autor:innen und Institutionen

  • Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
  • Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706, United States.
  • Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02108, United States.
  • Department of Earth and Planetary Science, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.
  • Department of Brain & Cognitive Sciences, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.
  • Department of Nuclear Science & Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States.

ORCID-Profile: Ilhan Bok, Alan Jasanoff, Aviad Hai

Förderung

  • NINDS NIH HHS
  • NIBIB NIH HHS
  • NIDA NIH HHS
  • National Institute of Neurological Disorders and Stroke
  • National Institute of Biomedical Imaging and Bioengineering
  • National Institute on Drug Abuse

Zitieren

APA

Bok, I., Phillips, J., Zhu, T., Lu, J., Detienne, E., Lima, E. A., Weiss, B. P., Jasanoff, A., & Hai, A. (2024). Magnetic Detection of Neural Activity by Nanocoil Transducers. Nano Letters. https://doi.org/10.1021/acs.nanolett.4c02784

Vancouver

Bok I, Phillips J, Zhu T, Lu J, Detienne E, Lima EA, et al. Magnetic Detection of Neural Activity by Nanocoil Transducers. Nano Letters. 2024. doi:10.1021/acs.nanolett.4c02784

BibTeX
@article{Bok2024,
  author = {Bok, Ilhan and Phillips, Jack and Zhu, Tianxiang and Lu, Jennifer and Detienne, Elizabeth and Lima, Eduardo Andrade and Weiss, Benjamin P and Jasanoff, Alan and Hai, Aviad},
  title = {Magnetic Detection of Neural Activity by Nanocoil Transducers},
  journal = {Nano Letters},
  year = {2024},
  doi = {10.1021/acs.nanolett.4c02784}
}
Kostenlos starten →