Highly Specific Non-Enzymatic Electrochemical Sensor for the Detection of Uric Acid Using Carboxylated Multiwalled Carbon Nanotubes Intertwined with GdS-Gd 2 O 3 Nanoplates in Human Urine and Serum
Langmuir · 15.10.2024 · 40 (41) · 21427-21441
DOI: 10.1021/acs.langmuir.4c02233 ↗Kurz gefasst
Fachartikel in der Zeitschrift Langmuir, online erschienen am 02.10.2024. Verfasst von Srishti Verma und 5 weiteren Autor:innen. Beteiligte Einrichtung: NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India. Hauptthemen laut MEDLINE: Nanotubes, Carbon, Uric Acid, Electrochemical Techniques, Gadolinium. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 79 Literaturangaben. Gefördert von: Department of Science and Technology, Ministry of Science and Technology, India, Indo-German Science and Technology Centre.
Abstract (Originalsprache)
Herein, the electrochemical sensing efficacy of carboxylic acid functionalized multiwalled carbon nanotubes (C-MWCNT) intertwined with coexisting phases of gadolinium monosulfide (GdS) and gadolinium oxide (Gd2O3) nanosheets is explored for the first time. The nanocomposite demonstrated splendid specificity for nonenzymatic electrochemical detection of uric acid (UA) in biological samples. It was synthesized using the coprecipitation method and thoroughly characterized. The presence of functional groups and disorder in the as-synthesized nanocomposite are confirmed using Fourier transform infrared spectroscopy and Raman spectroscopy. Furthermore, field emission scanning electron microscopy, high-resolution transmission electron microscope, X-ray powder diffraction, and X-ray photoelectron spectroscopy provides a clear understanding of the morphology, coexisting phases, and elemental composition of the as-synthesized nanocomposites. The differential pulse voltammetry technique was utilized to elaborate the electrochemical sensing of UA using a GdS-Gd2O3/C-MWCNT modified glassy carbon electrode (GCE), The sensor showed an enhanced current response by more than 2-fold compared to bare GCE. Also, the sensor's performance was further improved by dispersing the nanocomposite in an ionic liquid with the exceptional reproducibility (SD = 0.0025, n = 3). The fabricated UA sensor GdS-Gd2O3/C-MWCNT/IL/GCE demonstrated a wide linear detection range from 0.5-30 μM and 30-2000 μM, effectively covering the entire physiological range of UA in biological fluids with a limit of detection (LOD) of 0.380 μM (+3SD of blank) and a sensitivity of 356.125 μA mM-1 cm-2. Moreover, the electrodes exhibited storage stability for 2 weeks with decrease in zero-day current by only 4.5%. The sensor was validated by quantifying UA in 12 unprocessed clinical human urine and serum samples, and its comparison with the gold standard test yielded remarkable results (p < 0.05). Hence, the proposed nonenzymatic electrochemical UA sensor is selective, sensitive, reproducible, and stable, making it reliable for point-of-care diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
- School of Nano Science and Technology, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
- Department of Chemistry, Indian Institute of Technology Kharagpur, Kharagpur 721302, India.
- Nephro Care India Ltd., Kolkata 700098, India.
ORCID-Profile: Gorachand Dutta
Förderung
- Department of Science and Technology, Ministry of Science and Technology, India
- Indo-German Science and Technology Centre
Zitieren
APA
Verma, S., Sen, A., Dutta, N., Sengupta, P., Chakraborty, P., & Dutta, G. (2024). Highly Specific Non-Enzymatic Electrochemical Sensor for the Detection of Uric Acid Using Carboxylated Multiwalled Carbon Nanotubes Intertwined with GdS-Gd 2 O 3 Nanoplates in Human Urine and Serum. Langmuir, 40(41), 21427-21441. https://doi.org/10.1021/acs.langmuir.4c02233
Vancouver
Verma S, Sen A, Dutta N, Sengupta P, Chakraborty P, Dutta G. Highly Specific Non-Enzymatic Electrochemical Sensor for the Detection of Uric Acid Using Carboxylated Multiwalled Carbon Nanotubes Intertwined with GdS-Gd 2 O 3 Nanoplates in Human Urine and Serum. Langmuir. 2024;40(41):21427-21441. doi:10.1021/acs.langmuir.4c02233
BibTeX
@article{Verma2024,
author = {Verma, Srishti and Sen, Atreyee and Dutta, Nirmita and Sengupta, Pratim and Chakraborty, Pradip and Dutta, Gorachand},
title = {Highly Specific Non-Enzymatic Electrochemical Sensor for the Detection of Uric Acid Using Carboxylated Multiwalled Carbon Nanotubes Intertwined with GdS-Gd 2 O 3 Nanoplates in Human Urine and Serum},
journal = {Langmuir},
year = {2024},
volume = {40},
number = {41},
pages = {21427--21441},
doi = {10.1021/acs.langmuir.4c02233}
}
EUVIMED