EUVIMEDEUVIMED entdecken
Crossref

Ratiometric and simultaneous electrochemical analysis of uric acid and xanthine using poly(methylene blue) and reduced graphene oxide nanocomposite-modified screen-printed electrode

Geun Dae Kim, Sang Hyun Cho, Gi-Ja Lee

The Analyst · 2025

DOI: 10.1039/d5an00863h ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Analyst, 2025. Verfasst von Geun Dae Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Engineering, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea. gjlee@khu.ac.kr. Hauptthemen laut MEDLINE: Uric Acid, Graphite, Methylene Blue, Xanthine. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: National Research Foundation, Commercializations Promotion Agency for R and D Outcomes.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ratiometric PMB/rGO-CNT SPCE affords simultaneous UA and XT quantification by SWV. The PMB internal peak stabilizes signals and supports reliable performance in human serum.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Uric AcidGraphiteMethylene BlueXanthineNanocompositesElectrochemical TechniquesElectrodesHumansNanotubes, CarbonLimit of DetectionOxidation-ReductionCattleAnimals

Substanzen

Uric AcidGraphiteMethylene BlueXanthinegraphene oxideNanotubes, Carbon

Autor:innen und Institutionen

  • Department of Medical Engineering, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea. gjlee@khu.ac.kr.
  • Department of Precision Medicine, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea.
  • Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul 02447, Republic of Korea.

Förderung

  • National Research Foundation
  • Commercializations Promotion Agency for R and D Outcomes

Zitieren

APA

Kim, G. D., Cho, S. H., & Lee, G. J. (2025). Ratiometric and simultaneous electrochemical analysis of uric acid and xanthine using poly(methylene blue) and reduced graphene oxide nanocomposite-modified screen-printed electrode. The Analyst. https://doi.org/10.1039/d5an00863h

Vancouver

Kim GD, Cho SH, Lee GJ. Ratiometric and simultaneous electrochemical analysis of uric acid and xanthine using poly(methylene blue) and reduced graphene oxide nanocomposite-modified screen-printed electrode. The Analyst. 2025. doi:10.1039/d5an00863h

BibTeX
@article{Kim2025,
  author = {Kim, Geun Dae and Cho, Sang Hyun and Lee, Gi-Ja},
  title = {Ratiometric and simultaneous electrochemical analysis of uric acid and xanthine using poly(methylene blue) and reduced graphene oxide nanocomposite-modified screen-printed electrode},
  journal = {The Analyst},
  year = {2025},
  doi = {10.1039/d5an00863h}
}
Kostenlos starten →