EUVIMEDObjevte EUVIMED
Crossref

Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation

Bowen Du iD, Ibrahim Reda, Dusan Licina iD, Costa Kapsis, Dahai Qi, José A Candanedo, Tianyuan Li iD

Environmental Science & Technology · 2024

DOI: 10.1021/acs.est.4c02797 ↗

At a glance

Journal article in Environmental Science & Technology, 2024. Written by Bowen Du and 6 co-authors. Institution: Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, 1015 Lau…. Major MEDLINE topics: Carbon Dioxide, Ventilation, Air Pollution, Indoor, Environmental Monitoring. Cited 19 times so far (Crossref); 64 references.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

With a growing emphasis on indoor air quality (IAQ) in educational environments, CO2 monitoring in classrooms has become commonplace. CO2 data can be used to estimate outdoor air change rate (ACH) based on the mass balance principle, which can be further linked to human health, performance, and building energy consumption. This study used a novel machine learning method to automatically segment CO2 concentration time series data into build-up, equilibrium, and decay periods, and then estimated classroom ACH using the corresponding CO2 mass balance equations. This method, applied to 40 classrooms in two mechanically ventilated K-6 schools, generated up to ten ACH estimates per day per classroom. A comparison with ACH calculated using the mechanical ventilation rates with 100% outdoor air reported by the building automation system during the study period reveals a slight underestimation by the decay and build-up methods, while the equilibrium method produced closer estimates. These differences may be attributed to uncertainties in occupancy, activity, CO2 emission rates, and air mixing. This research underscores the potential of leveraging CO2 data for more comprehensive IAQ assessments and highlights the challenges associated with accurately estimating ACH in real-world settings.

Subjects

MeSH terms (MEDLINE)

Carbon DioxideVentilationAir Pollution, IndoorEnvironmental MonitoringSchoolsHumans

Author keywords

carbon dioxideclusteringdata-drivenmachine learningmass balanceschool ventilationtracer gas

Substances

Carbon Dioxide

Authors and institutions

  • Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
  • Département de génie civil et génie du bâtiment, Faculté de génie, Université de Sherbrooke, Sherbrooke J1K 2R1 Québec, Canada.
  • Department of Civil and Environmental Engineering, University of Waterloo, Waterloo N2L 3G1 Ontario, Canada.

ORCID profiles: Bowen Du, Dusan Licina, Tianyuan Li

Cite

APA

Du, B., Reda, I., Licina, D., Kapsis, C., Qi, D., Candanedo, J. A., & Li, T. (2024). Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation. Environmental Science & Technology. https://doi.org/10.1021/acs.est.4c02797

Vancouver

Du B, Reda I, Licina D, Kapsis C, Qi D, Candanedo JA, et al. Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation. Environmental Science & Technology. 2024. doi:10.1021/acs.est.4c02797

BibTeX
@article{Du2024,
  author = {Du, Bowen and Reda, Ibrahim and Licina, Dusan and Kapsis, Costa and Qi, Dahai and Candanedo, José A and Li, Tianyuan},
  title = {Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation},
  journal = {Environmental Science & Technology},
  year = {2024},
  doi = {10.1021/acs.est.4c02797}
}
Start for free →