Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation
Environmental Science & Technology · 2024
DOI: 10.1021/acs.est.4c02797 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, 2024. Verfasst von Bowen Du und 6 weiteren Autor:innen. Beteiligte Einrichtung: Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, 1015 Lau…. Hauptthemen laut MEDLINE: Carbon Dioxide, Ventilation, Air Pollution, Indoor, Environmental Monitoring. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 64 Literaturangaben.
Abstract (Originalsprache)
With a growing emphasis on indoor air quality (IAQ) in educational environments, CO2 monitoring in classrooms has become commonplace. CO2 data can be used to estimate outdoor air change rate (ACH) based on the mass balance principle, which can be further linked to human health, performance, and building energy consumption. This study used a novel machine learning method to automatically segment CO2 concentration time series data into build-up, equilibrium, and decay periods, and then estimated classroom ACH using the corresponding CO2 mass balance equations. This method, applied to 40 classrooms in two mechanically ventilated K-6 schools, generated up to ten ACH estimates per day per classroom. A comparison with ACH calculated using the mechanical ventilation rates with 100% outdoor air reported by the building automation system during the study period reveals a slight underestimation by the decay and build-up methods, while the equilibrium method produced closer estimates. These differences may be attributed to uncertainties in occupancy, activity, CO2 emission rates, and air mixing. This research underscores the potential of leveraging CO2 data for more comprehensive IAQ assessments and highlights the challenges associated with accurately estimating ACH in real-world settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Human-Oriented Built Environment Lab, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland.
- Département de génie civil et génie du bâtiment, Faculté de génie, Université de Sherbrooke, Sherbrooke J1K 2R1 Québec, Canada.
- Department of Civil and Environmental Engineering, University of Waterloo, Waterloo N2L 3G1 Ontario, Canada.
ORCID-Profile: Bowen Du, Dusan Licina, Tianyuan Li
Zitieren
APA
Du, B., Reda, I., Licina, D., Kapsis, C., Qi, D., Candanedo, J. A., & Li, T. (2024). Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation. Environmental Science & Technology. https://doi.org/10.1021/acs.est.4c02797
Vancouver
Du B, Reda I, Licina D, Kapsis C, Qi D, Candanedo JA, et al. Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation. Environmental Science & Technology. 2024. doi:10.1021/acs.est.4c02797
BibTeX
@article{Du2024,
author = {Du, Bowen and Reda, Ibrahim and Licina, Dusan and Kapsis, Costa and Qi, Dahai and Candanedo, José A and Li, Tianyuan},
title = {Estimating Air Change Rate in Mechanically Ventilated Classrooms Using a Single CO 2 Sensor and Automated Data Segmentation},
journal = {Environmental Science & Technology},
year = {2024},
doi = {10.1021/acs.est.4c02797}
}
EUVIMED