EUVIMEDOpdag EUVIMED
Open access · CC BY-NC-ND 4.0

Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach

Courtney C Carignan iD, Rachel A Bauer, Andrew Patterson, Thep Phomsopha, Eric Redman, Heather M Stapleton iD, Christopher P Higgins iD

Environmental Science & Technology · 2023-05-30 · 57 (21) · 7950-7957

DOI: 10.1021/acs.est.2c09852 ↗

At a glance

Journal article in Environmental Science & Technology, published online on 2023-05-16. Written by Courtney C Carignan and 6 co-authors. Institution: Department Food Science and Human Nutrition, Michigan State University, East Lansing, Michigan 48864, United States. Major MEDLINE topics: Hematologic Tests, Fluorocarbons. Cited 39 times so far (Crossref); 29 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIEHS NIH HHS, EPA, National Institute of Environmental Health Sciences.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

A remote sampling approach was developed at Eurofins for quantifying per- and polyfluoroalkyl substances (PFASs) in whole blood samples collected using volumetric absorptive microsamplers (VAMSs), which allow for self-collection of blood using a finger prick. This study compares PFAS exposure measured by self-collection of blood using VAMSs to the standard venous serum approach. Blood samples were collected from participants (n = 53) in a community with prior PFAS drinking water contamination using a venous blood draw as well as participant self-collection using VAMSs. Whole blood from the venous tubes was also loaded onto VAMSs to compare differences in capillary vs venous whole blood PFAS levels. Samples were quantified for PFASs using liquid chromatography tandem mass spectrometry and online solid-phase extraction. PFAS levels in serum were highly correlated with measurements in capillary VAMSs (r ≥ 0.91 and p < 0.05). Serum PFAS levels were generally twofold higher than whole blood, reflecting expected differences in their composition. Of interest, FOSA was detected in whole blood (both venous and capillary VAMSs) but not in serum. Overall, these findings indicate that VAMSs are useful self-collection tools for assessing elevated human exposure to PFASs.

Subjects

MeSH terms (MEDLINE)

Hematologic TestsFluorocarbonsHumansMass SpectrometryChromatography, Liquid

Author keywords

MitraPFASbiomonitoringbloodexposuremicrosamplingserum

Substances

Fluorocarbons

Authors and institutions

  • Department Food Science and Human Nutrition, Michigan State University, East Lansing, Michigan 48864, United States.
  • Department of Pharmacology and Toxicology, Michigan State University, East Lansing, Michigan 48864, United States.
  • Eurofins Environment Testing America, West Sacramento, California 95605, United States.
  • Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States.
  • Department of Civil & Environmental Engineering, Colorado School of Mines, Golden, Colorado 80401, United States.

ORCID profiles: Courtney C Carignan, Heather M Stapleton, Christopher P Higgins

Funding

  • NIEHS NIH HHS
  • EPA
  • National Institute of Environmental Health Sciences
  • National Institute of Food and Agriculture
  • U.S. Environmental Protection Agency

Cite

APA

Carignan, C. C., Bauer, R. A., Patterson, A., Phomsopha, T., Redman, E., Stapleton, H. M., & Higgins, C. P. (2023). Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach. Environmental Science & Technology, 57(21), 7950-7957. https://doi.org/10.1021/acs.est.2c09852

Vancouver

Carignan CC, Bauer RA, Patterson A, Phomsopha T, Redman E, Stapleton HM, et al. Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach. Environmental Science & Technology. 2023;57(21):7950-7957. doi:10.1021/acs.est.2c09852

BibTeX
@article{Carignan2023,
  author = {Carignan, Courtney C and Bauer, Rachel A and Patterson, Andrew and Phomsopha, Thep and Redman, Eric and Stapleton, Heather M and Higgins, Christopher P},
  title = {Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach},
  journal = {Environmental Science & Technology},
  year = {2023},
  volume = {57},
  number = {21},
  pages = {7950--7957},
  doi = {10.1021/acs.est.2c09852}
}
Start for free →