EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Premium ultra-trace analytical method for part per quadrillion (ppq) PFAS quantification in drinking water

Wejdan Alghamdi, Jordan M Partington, Ivanhoe K H Leung, Bradley O Clarke

Analytica Chimica Acta · 2025

DOI: 10.1016/j.aca.2025.344333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025. Verfasst von Wejdan Alghamdi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia; Department of Chemistry, Co…. Hauptthemen laut MEDLINE: Drinking Water, Fluorocarbons, Water Pollutants, Chemical. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Agilent Technologies.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Recent improvements in analytical methods have made it possible to detect very low levels of contaminants in drinking water, allowing for more accurate tracking of per-and polyfluoroalkyl substances (PFAS). This study optimized a sensitive sub ng/L method for the quantification of 75 PFAS (from 80 that were evaluated) in drinking water using solid phase extraction (SPE) and liquid chromatography triple quadrupole mass spectrometry (LCTQ). Based on USEPA 533/537 analytical methods for drinking water, the optimisation process included vial materials, evaporation parameters, and the selection of SPE sorbents and eluents. These conditions were then utilized to achieve ppq-level quantification for PFOS, PFOA, Gen-X, PFBS, PFNA, and PFHxS. RESULTS: Addition of 20 % water as a keeper solvent following SPE and through evaporation increased analyte recovery, especially for semi-volatile PFAS. Sequential elution solvents of 4 mL 0.1 % NH4OH in MeOH/ACN (50:50 v/v) followed by 4 mL ACN, resulted in acceptable recoveries (70-130 %) of 75 legacy and emerging PFAS. The optimized method achieved limits of detection lower than previous similar studies, enabling quantification of PFAS at premium ultra trace pg/L levels ranging from 0.0038 to 0.0155 ng/L with recoveries ranging from 87 to 119 %. This optimized procedure was used on 27 drinking water samples from Victoria's Gippsland region in Australia, detecting 50 of the 75 targeted PFAS. Notably, 12 PFAS were detec in drinking water (tap and bottled) for the first time globally ( L-PFTrDS, 8Cl-PFOS, 10:2 FTUCA, MeFBSA, EtFOSA, EtFOSE, AP-FHxSA, TAMP-FHxSA, 8:2 Cl-PFESA, NFDHA, 8:8 PFPi and diSAmPAP). While most of the samples examined in the investigation did not pose a threat to human health based on the present standards, half of the collected samples had PFOS and PFOA concentrations higher than the advisory contaminant levels set by the US EPA in 2022 (4 pg/L). SIGNIFICANCE: This work improves the efficiency of targeted PFAS analysis, enhancing the capabilities of monitoring a wide range of PFAS including legacy and emerging compounds, and contributing to public health safety. By optimizing the premium ultra trace pq/L levels, this methodology presents a valuable tool for PFAS assessment to meet regulation requirements in the future.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drinking WaterFluorocarbonsWater Pollutants, ChemicalSolid Phase ExtractionLimit of DetectionChromatography, LiquidMass Spectrometry

Stichwörter der Autor:innen

Drinking waterPFASSPE optimisationUltra-trace detection limitppq

Substanzen

Drinking WaterFluorocarbonsWater Pollutants, Chemical

Autor:innen und Institutionen

  • Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia; Department of Chemistry, College of Science, University of Bisha, Bisha, P.O. Box 551, 61922, Sau…
  • Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia.
  • Bio21 Molecular Science and Biotechnology Institute, School of Chemistry, The University of Melbourne, Flemington Road, Victoria, 3052, Australia.
  • Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria, 3010, Australia. Electronic address: brad.clarke@unimelb.edu.au.

Förderung

  • Agilent Technologies

Zitieren

APA

Alghamdi, W., Partington, J. M., Leung, I. K. H., & Clarke, B. O. (2025). Premium ultra-trace analytical method for part per quadrillion (ppq) PFAS quantification in drinking water. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2025.344333

Vancouver

Alghamdi W, Partington JM, Leung IKH, Clarke BO. Premium ultra-trace analytical method for part per quadrillion (ppq) PFAS quantification in drinking water. Analytica Chimica Acta. 2025. doi:10.1016/j.aca.2025.344333

BibTeX
@article{Alghamdi2025,
  author = {Alghamdi, Wejdan and Partington, Jordan M and Leung, Ivanhoe K H and Clarke, Bradley O},
  title = {Premium ultra-trace analytical method for part per quadrillion (ppq) PFAS quantification in drinking water},
  journal = {Analytica Chimica Acta},
  year = {2025},
  doi = {10.1016/j.aca.2025.344333}
}
Kostenlos starten →