Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach
Environmental Science & Technology · 30.05.2023 · 57 (21) · 7950-7957
DOI: 10.1021/acs.est.2c09852 ↗Kurz gefasst
Fachartikel in der Zeitschrift Environmental Science & Technology, online erschienen am 16.05.2023. Verfasst von Courtney C Carignan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department Food Science and Human Nutrition, Michigan State University, East Lansing, Michigan 48864, United States. Hauptthemen laut MEDLINE: Hematologic Tests, Fluorocarbons. Die Arbeit wurde bisher 39-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIEHS NIH HHS, EPA, National Institute of Environmental Health Sciences.
Abstract (Originalsprache)
A remote sampling approach was developed at Eurofins for quantifying per- and polyfluoroalkyl substances (PFASs) in whole blood samples collected using volumetric absorptive microsamplers (VAMSs), which allow for self-collection of blood using a finger prick. This study compares PFAS exposure measured by self-collection of blood using VAMSs to the standard venous serum approach. Blood samples were collected from participants (n = 53) in a community with prior PFAS drinking water contamination using a venous blood draw as well as participant self-collection using VAMSs. Whole blood from the venous tubes was also loaded onto VAMSs to compare differences in capillary vs venous whole blood PFAS levels. Samples were quantified for PFASs using liquid chromatography tandem mass spectrometry and online solid-phase extraction. PFAS levels in serum were highly correlated with measurements in capillary VAMSs (r ≥ 0.91 and p < 0.05). Serum PFAS levels were generally twofold higher than whole blood, reflecting expected differences in their composition. Of interest, FOSA was detected in whole blood (both venous and capillary VAMSs) but not in serum. Overall, these findings indicate that VAMSs are useful self-collection tools for assessing elevated human exposure to PFASs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department Food Science and Human Nutrition, Michigan State University, East Lansing, Michigan 48864, United States.
- Department of Pharmacology and Toxicology, Michigan State University, East Lansing, Michigan 48864, United States.
- Eurofins Environment Testing America, West Sacramento, California 95605, United States.
- Nicholas School of the Environment, Duke University, Durham, North Carolina 27708, United States.
- Department of Civil & Environmental Engineering, Colorado School of Mines, Golden, Colorado 80401, United States.
ORCID-Profile: Courtney C Carignan, Heather M Stapleton, Christopher P Higgins
Förderung
- NIEHS NIH HHS
- EPA
- National Institute of Environmental Health Sciences
- National Institute of Food and Agriculture
- U.S. Environmental Protection Agency
Zitieren
APA
Carignan, C. C., Bauer, R. A., Patterson, A., Phomsopha, T., Redman, E., Stapleton, H. M., & Higgins, C. P. (2023). Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach. Environmental Science & Technology, 57(21), 7950-7957. https://doi.org/10.1021/acs.est.2c09852
Vancouver
Carignan CC, Bauer RA, Patterson A, Phomsopha T, Redman E, Stapleton HM, et al. Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach. Environmental Science & Technology. 2023;57(21):7950-7957. doi:10.1021/acs.est.2c09852
BibTeX
@article{Carignan2023,
author = {Carignan, Courtney C and Bauer, Rachel A and Patterson, Andrew and Phomsopha, Thep and Redman, Eric and Stapleton, Heather M and Higgins, Christopher P},
title = {Self-Collection Blood Test for PFASs: Comparing Volumetric Microsamplers with a Traditional Serum Approach},
journal = {Environmental Science & Technology},
year = {2023},
volume = {57},
number = {21},
pages = {7950--7957},