A wearable real-time kinetic measurement sensor setup for human locomotion

Huawei Wang, Akash Basu, Guillaume Durandau, Massimo Sartori

Wearable Technologies · 2023 · 4

DOI: 10.1017/wtc.2023.7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wearable Technologies, online erschienen am 11.04.2023. Verfasst von Huawei Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomechanical Engineering, University of Twente, Enschede, the Netherlands. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: H2020 European Research Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Current laboratory-based setups (optical marker cameras + force plates) for human motion measurement require participants to stay in a constrained capture region which forbids rich movement types. This study established a fully wearable system, based on commercially available sensors (inertial measurement units + pressure insoles), that can measure both kinematic and kinetic motion data simultaneously and support wireless frame-by-frame streaming. In addition, its capability and accuracy were tested against a conventional laboratory-based setup. An experiment was conducted, with 9 participants wearing the wearable measurement system and performing 13 daily motion activities, from slow walking to fast running, together with vertical jump, squat, lunge, and single-leg landing, inside the capture space of the laboratory-based motion capture system. The recorded sensor data were post-processed to obtain joint angles, ground reaction forces (GRFs), and joint torques (via multi-body inverse dynamics). Compared to the laboratory-based system, the established wearable measurement system can measure accurate information of all lower limb joint angles (Pearson’s r = 0.929), vertical GRFs (Pearson’s r = 0.954), and ankle joint torques (Pearson’s r = 0.917). Center of pressure (CoP) in the anterior–posterior direction and knee joint torques were fairly matched (Pearson’s r = 0.683 and 0.612, respectively). Calculated hip joint torques and measured medial–lateral CoP did not match with the laboratory-based system (Pearson’s r = 0.21 and 0.47, respectively). Furthermore, both raw and processed datasets are openly accessible ( https://doi.org/10.5281/zenodo.6457662 ). Documentation, data processing codes, and guidelines to establish the real-time wearable kinetic measurement system are also shared ( https://github.com/HuaweiWang/WearableMeasurementSystem ).

Autor:innen und Institutionen

  • Department of Biomechanical Engineering, University of Twente, Enschede, the Netherlands.
  • Department of Mechanical Engineering, McGill University, Montreal, Canada.

Förderung

  • H2020 European Research Council

Zitieren

APA

Wang, H., Basu, A., Durandau, G., & Sartori, M. (2023). A wearable real-time kinetic measurement sensor setup for human locomotion. Wearable Technologies, 4. https://doi.org/10.1017/wtc.2023.7

Vancouver

Wang H, Basu A, Durandau G, Sartori M. A wearable real-time kinetic measurement sensor setup for human locomotion. Wearable Technologies. 2023;4. doi:10.1017/wtc.2023.7

BibTeX
@article{Wang2023,
  author = {Wang, Huawei and Basu, Akash and Durandau, Guillaume and Sartori, Massimo},
  title = {A wearable real-time kinetic measurement sensor setup for human locomotion},
  journal = {Wearable Technologies},
  year = {2023},
  volume = {4},
  doi = {10.1017/wtc.2023.7}
}
Kostenlos starten →