EUVIMEDEUVIMED entdecken
Crossref

A flexible multichannel wearable sensor for real-time monitoring of exercise-induced sweat composition

Pengjia Qi, Canjie Hu, Zhanlu Yu, Yang Chen, Chonghui Zhu, Lichao Liu

Talanta · 2026-05 · 302 · 129355

DOI: 10.1016/j.talanta.2026.129355 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Talanta, 2026-05. Verfasst von Pengjia Qi und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Science and Engineering (School of Cyber Science and Technology), Zhejiang Sci-Tech University, Hangzhou, 310018, China. Electr…. Hauptthemen laut MEDLINE: Sweat, Wearable Electronic Devices, Biosensing Techniques, Exercise. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Key Research and Development Program of Zhejiang Province, National Natural Science Foundation of China, Zhejiang Sci-Tech University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address low sensitivity, severe environmental interference, single-analyte detection, and traditional rigid substrates' inability to adapt to dynamic skin deformation in surface metabolite detection, polyethylene terephthalate (PET) was selected as the flexible substrate. A multi-channel flexible wearable biosensor with mechanical adaptability and multi-parameter detection capability was constructed via screen-printing, integrating four independent working electrodes sharing one reference and counter electrode, enabling real-time quantification of K+, NH4+, lactic acid (LA), and ascorbic acid (AA) in human sweat. Experimental results demonstrate the sensor's excellent detection performance. For K+, the sensitivity is 89.9 mV decade-1 within the concentration range of 0.5-12 mM; for NH4+, it is 55.9 mV decade-1 over 0.2-4 mM; for LA, the sensitivity reaches 86 nA mM-1 across 5-40 mM; and for AA, the sensitivities are 2.62 μA μM-1 (2-10 μM) and 1.17 μA μM-1 (10-60 μM), respectively. Notably, all detection limits and linear ranges align with human sweat's physiological concentration range. Moreover, the sensor demonstrates excellent selectivity toward target analytes, long-term stability, and good reproducibility. Flexibility tests show 0°-120° bending and 100 cycles have negligible effects. Moreover, placing the sensor on the subjects' forehead enabled non-invasive continuous monitoring of sweat K+, NH4+, LA, and AA dynamics during 30-min exercise. This work verifies the sensor's potential in sports health monitoring and personalized athletic performance tracking, while advancing wearable sensing technology toward higher precision and integration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatWearable Electronic DevicesBiosensing TechniquesExerciseHumansAscorbic AcidPotassiumLactic AcidReproducibility of ResultsPolyethylene TerephthalatesElectrodes

Stichwörter der Autor:innen

Ammonium ionsAscorbic acidLactic acidMulti-channel flexible sensorPotassium ionsSweat

Substanzen

Ascorbic AcidPotassiumLactic AcidPolyethylene Terephthalates

Autor:innen und Institutionen

  • School of Information Science and Engineering (School of Cyber Science and Technology), Zhejiang Sci-Tech University, Hangzhou, 310018, China. Electronic address: qipengjia@zstu.edu.cn.
  • School of Information Science and Engineering (School of Cyber Science and Technology), Zhejiang Sci-Tech University, Hangzhou, 310018, China.
  • School of Computer Science and Technology (School of Artificial Intelligence), Zhejiang Sci-Tech University, Hangzhou, 310018, China.
  • School of Environmental Science and Technology, Dalian University of Technology, Dalian, 116024, China. Electronic address: zhuch@dlut.edu.cn.
  • College of Naval Architecture and Ocean Engineering, Naval University of Engineering, Wuhan, 430033, China. Electronic address: liulichao552@163.com.

Förderung

  • Key Research and Development Program of Zhejiang Province
  • National Natural Science Foundation of China
  • Zhejiang Sci-Tech University

Zitieren

APA

Qi, P., Hu, C., Yu, Z., Chen, Y., Zhu, C., & Liu, L. (2026). A flexible multichannel wearable sensor for real-time monitoring of exercise-induced sweat composition. Talanta, 302, 129355. https://doi.org/10.1016/j.talanta.2026.129355

Vancouver

Qi P, Hu C, Yu Z, Chen Y, Zhu C, Liu L. A flexible multichannel wearable sensor for real-time monitoring of exercise-induced sweat composition. Talanta. 2026;302:129355. doi:10.1016/j.talanta.2026.129355

BibTeX
@article{Qi2026,
  author = {Qi, Pengjia and Hu, Canjie and Yu, Zhanlu and Chen, Yang and Zhu, Chonghui and Liu, Lichao},
  title = {A flexible multichannel wearable sensor for real-time monitoring of exercise-induced sweat composition},
  journal = {Talanta},
  year = {2026},
  volume = {302},
  pages = {129355},
  doi = {10.1016/j.talanta.2026.129355}
}
Kostenlos starten →