EUVIMEDEUVIMED entdecken
Crossref

Awake Robotic Minimally Invasive Transforaminal Lumbar Interbody Fusion Under Spinal Anesthesia: A Prospective Study with 1-Year Follow-up

Gaetano De Biase, Oluwaseun O Akinduro, Diogo Garcia, Elird Bojaxhi, Ian A Buchanan, Shaun E Gruenbaum, Teodoro Forcht Dagi, Alfredo Quinones-Hinojosa, Kingsley Abode-Iyamah

World Neurosurgery · 2024

DOI: 10.1016/j.wneu.2024.07.044 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Neurosurgery, 2024. Verfasst von Gaetano De Biase und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery, Mayo Clinic, Jacksonville, Florida, USA. Hauptthemen laut MEDLINE: Spinal Fusion, Robotic Surgical Procedures, Lumbar Vertebrae, Minimally Invasive Surgical Procedures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: We describe our protocol and outcomes of awake robotic minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) under spinal anesthesia. METHODS: We conducted a prospective study of 10 consecutive patients undergoing awake robotic single-level MIS-TLIF with the Mazor X robot. We prospectively collected patient-reported outcomes (back and leg pain visual analog scale and Oswestry Disability Index) preoperatively at 1-month and 1-year follow-ups and assessed fusion and screw placement accuracy with a 1-year computed tomography (CT) scan. RESULTS: Median age was 61 years (interquartile range [IQR] = 57.7-66). Median body mass index was 27 kg/m2. No intraoperative complications were reported. Most (9/10) patients were discharged home, and 50% discharged on the day of surgery. Median length of stay was 16.5 hours (IQR = 5-35.5). Median follow-up was 12.5 months (IQR = 12-13.5), with 9 patients having at least 12-month follow-up, with CT scans documenting good screw placement (Gertzbein-Robbins grade A) and solid bony fusion. Median preoperative back pain visual analog scale score was 7.8 (IQR = 6.9-8) versus 1.5 (IQR = 0-3.2) at 1-month post operation, P < 0.01, and 0 (IQR = 0-1) at 1-year follow-up, P < 0.01; median preoperative leg pain 8 (IQR = 7.4-8) versus 0 (IQR = 0-1.2) at 1-month post operation, P < 0.01, and 0 (IQR = 0-2) at 1-year follow-up, P < 0.01; median preoperative Oswestry Disability Index 47.5 (IQR = 27.8-57.5) versus 4 (IQR = 0-16) at 1-month postoperation, P < 0.01, and 0 (IQR = 0-7) at 1-year follow-up, P < 0.01. Median preoperative disk height of the index level was 8 mm (IQR = 2.4-9.5) versus 11.4 mm (IQR = 9.2-11.2) postoperatively,P < 0.01. Median preoperative lordosis of the index level was 5 degrees (IQR = 3.4-8.5) versus 10.1 degrees (7.3-12.2) postoperatively, P < 0.01. CONCLUSIONS: Our study showed significant improvement in patient-reported outcomes at 1-month and 1-year follow-ups after awake robotic MIS-TLIF, as well as solid bony fusion on CT scans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal FusionRobotic Surgical ProceduresLumbar VertebraeMinimally Invasive Surgical ProceduresAnesthesia, SpinalHumansMiddle AgedMaleFemaleAgedProspective StudiesFollow-Up StudiesWakefulnessTreatment Outcome

Stichwörter der Autor:innen

Awake fusionAwake spineRobotic fusionRoboticsSpinal fusionSpine

Autor:innen und Institutionen

  • Department of Neurosurgery, Mayo Clinic, Jacksonville, Florida, USA.
  • Department of Anesthesiology, Mayo Clinic, Jacksonville, Florida, USA.
  • Department of Neurosurgery, Mayo Clinic, Jacksonville, Florida, USA. Electronic address: abode-iyamah.kingsley@mayo.edu.

Zitieren

APA

De Biase, G., Akinduro, O. O., Garcia, D., Bojaxhi, E., Buchanan, I. A., Gruenbaum, S. E., Forcht Dagi, T., Quinones-Hinojosa, A., & Abode-Iyamah, K. (2024). Awake Robotic Minimally Invasive Transforaminal Lumbar Interbody Fusion Under Spinal Anesthesia: A Prospective Study with 1-Year Follow-up. World Neurosurgery. https://doi.org/10.1016/j.wneu.2024.07.044

Vancouver

De Biase G, Akinduro OO, Garcia D, Bojaxhi E, Buchanan IA, Gruenbaum SE, et al. Awake Robotic Minimally Invasive Transforaminal Lumbar Interbody Fusion Under Spinal Anesthesia: A Prospective Study with 1-Year Follow-up. World Neurosurgery. 2024. doi:10.1016/j.wneu.2024.07.044

BibTeX
@article{DeBiase2024,
  author = {De Biase, Gaetano and Akinduro, Oluwaseun O and Garcia, Diogo and Bojaxhi, Elird and Buchanan, Ian A and Gruenbaum, Shaun E and Forcht Dagi, Teodoro and Quinones-Hinojosa, Alfredo and Abode-Iyamah, Kingsley},
  title = {Awake Robotic Minimally Invasive Transforaminal Lumbar Interbody Fusion Under Spinal Anesthesia: A Prospective Study with 1-Year Follow-up},
  journal = {World Neurosurgery},
  year = {2024},
  doi = {10.1016/j.wneu.2024.07.044}
}
Kostenlos starten →