EUVIMEDEUVIMED entdecken
Crossref

Evaluation of oesophageal Doppler-derived variables and plethysmographic variability index to predict fluid responsiveness in mechanically ventilated healthy dogs

Ignacio Sández, Rocío Bustamante, Pablo A Donati, Daniel Torralbo, Maria Soto, Aitor Fernández-Novo, Eva Rioja

Veterinary Anaesthesia and Analgesia · 2025

DOI: 10.1016/j.vaa.2025.03.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2025. Verfasst von Ignacio Sández und 6 weiteren Autor:innen. Beteiligte Einrichtung: Anaesthesiology Service, Veterinary Department, Biomedical and Health Sciences Faculty, Universidad Europea de Madrid, Villaviciosa de Odón, Spain. E…. Hauptthemen laut MEDLINE: Respiration, Artificial, Fluid Therapy, Plethysmography, Anesthesia, General. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To evaluate the plethysmography variability index (PVI) and oesophageal Doppler (OD)-derived dynamic variables [stroke distance variation (StDV) and aortic flow peak velocity variation (PVV)] as predictors of fluid responsiveness. STUDY DESIGN: A prospective cohort, diagnostic test study. ANIMALS: A group of 30 client-owned dogs undergoing general anaesthesia. METHODS: Dogs received dexmedetomidine (3 μg kg-1) and methadone (0.3 mg kg-1), intramuscularly. Anaesthesia was induced with propofol and maintained with isoflurane. Volume-controlled ventilation was instituted with tidal volume 10 mL kg-1, inspiratory-to-expiratory ratio 1:2. Heart rate (HR) and mean arterial pressure (MAP) were monitored. An OD probe was inserted to measure stroke distance (StD). Once surgery finished, PVV, StDV and PVI were recorded before (T0) and after (T1) the administration of 3 mL kg-1 bolus of hydroxyethyl starch 6% over 5 minutes. Dogs were classified as fluid-responders (R; StD increased ≥ 15%) or non-fluid-responders (NR). Receiver operating characteristic (ROC) curves were plotted for PVV, StDV and PVI. RESULTS: Of the 30 animals, eight were classified as R and 22 as NR. The areas under the ROC curves for PVV, StDV and PVI were 0.87 [confidence interval (CI) 0.82-1], 0.84 (CI 0.67-1) and 0.78 (CI 0.62-1), respectively. The best cut-offs (positive-negative predictive values) were 9% (54-94%) for PVV (sensitivity, 88%; specificity, 73%), 12% (58-94%) for StDV (sensitivity, 88%; specificity, 77%) and 15% (60-90%) for PVI (sensitivity, 75%; specificity, 82%). No statistical differences were found between R and NR, nor between T0 and T1, for MAP or HR. CONCLUSIONS AND CLINICAL RELEVANCE: OD-derived values of PVV, StDV and PVI are reasonable predictors of fluid responsiveness in client-owned dogs undergoing general anaesthesia and mechanical ventilation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Respiration, ArtificialFluid TherapyPlethysmographyAnesthesia, GeneralUltrasonography, DopplerEsophagusAnimalsDogsFemaleMaleProspective Studies

Stichwörter der Autor:innen

anaesthesiadogfluid responsivenessgoal-directed fluid therapyoesophageal Doppler

Autor:innen und Institutionen

  • Anaesthesiology Service, Veterinary Department, Biomedical and Health Sciences Faculty, Universidad Europea de Madrid, Villaviciosa de Odón, Spain. Electronic address: nsandezcordero2@gmail.com.
  • Department of Animal Medicine and Surgery, Veterinary Teaching Hospital, Complutense University of Madrid, Madrid, Spain.
  • Department of Anaesthesiology and Pain Management, Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Buenos Aires 1427, Argentina.
  • Servicio Itinerante de Anestesia Hypnos Veterinaria, Madrid, Spain.
  • Independent Researcher, Spain.
  • Anaesthesiology Service, Veterinary Department, Biomedical and Health Sciences Faculty, Universidad Europea de Madrid, Villaviciosa de Odón, Spain.

Zitieren

APA

Sández, I., Bustamante, R., Donati, P. A., Torralbo, D., Soto, M., Fernández-Novo, A., & Rioja, E. (2025). Evaluation of oesophageal Doppler-derived variables and plethysmographic variability index to predict fluid responsiveness in mechanically ventilated healthy dogs. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2025.03.003

Vancouver

Sández I, Bustamante R, Donati PA, Torralbo D, Soto M, Fernández-Novo A, et al. Evaluation of oesophageal Doppler-derived variables and plethysmographic variability index to predict fluid responsiveness in mechanically ventilated healthy dogs. Veterinary Anaesthesia and Analgesia. 2025. doi:10.1016/j.vaa.2025.03.003

BibTeX
@article{Sndez2025,
  author = {Sández, Ignacio and Bustamante, Rocío and Donati, Pablo A and Torralbo, Daniel and Soto, Maria and Fernández-Novo, Aitor and Rioja, Eva},
  title = {Evaluation of oesophageal Doppler-derived variables and plethysmographic variability index to predict fluid responsiveness in mechanically ventilated healthy dogs},
  journal = {Veterinary Anaesthesia and Analgesia},
  year = {2025},
  doi = {10.1016/j.vaa.2025.03.003}
}
Kostenlos starten →