Diagnostic accuracy of pulse pressure variation, stroke volume variation and plethysmography variability index for prediction of fluid responsiveness in anesthetized and mechanically ventilated dogs: a systematic review and meta-analysis
Veterinary Anaesthesia and Analgesia · 2026
DOI: 10.1016/j.vaa.2025.10.006 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Veterinary Anaesthesia and Analgesia, 2026. Verfasst von Pablo A Donati und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Management, Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Buenos Aires, Argentina. Electronic…. Hauptthemen laut MEDLINE: Stroke Volume, Blood Pressure, Fluid Therapy, Respiration, Artificial. Die Arbeit nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Secretaria de Ciencia y Tecnica, Universidad de Buenos Aires.
Themen: Schlaganfall
Abstract (Originalsprache)
OBJECTIVE: To assess the diagnostic accuracy of pulse pressure variation (PPV), plethysmographic variability index (PVI) and stroke volume variation (SVV) for predicting fluid responsiveness in dogs. STUDY DESIGN: Systematic review and meta-analysis of diagnostic test accuracy studies. ANIMALS: Anesthetized dogs undergoing surgery, in critical care, or in experimental settings. METHODS: The study protocol was registered in Open Science Framework (https://doi.org/10.17605/OSF.IO/4DBGP). Databases (Medline, Embase, LILACS, Web of Science and Scopus) were searched from inception to 14 April 2025. Study quality was assessed using standardized criteria. Pooled sensitivity and specificity were calculated using a bivariate random-effects model. Likelihood ratios (LR), diagnostic odds ratios (DOR) and summary receiver operating characteristic (sROC) curves were generated. Confidence intervals (CIs) were calculated. RESULTS: Risk of bias was high in all studies of PPV, PVI and SVV. In four clinical PPV studies, sensitivity was 0.88 (95% CI: 0.65-0.97), specificity 0.97 (95% CI: 0.83-0.99), LR+ 30.99 (95% CI: 5.25-182.85), LR- 0.11 (95% CI: 0.02-0.40) and DOR 263 (95% CI: 26-1890). In five experimental PPV studies, sensitivity was 0.78 (95% CI: 0.64-0.87), specificity 0.83 (95% CI: 0.70-0.91), LR+ 4.63 (95% CI: 2.41-8.88), LR- 0.27 (95% CI: 0.16-0.46) and DOR 17 (95% CI: 6-48). For PVI (five studies), sensitivity was 0.83 (95% CI: 0.75-0.89), specificity 0.85 (95% CI: 0.78-0.90) and DOR 29 (95% CI: 13-64). For SVV (10 studies), sensitivity was 0.77 (95% CI: 0.69-0.84), specificity 0.81 (95% CI: 0.68-0.89) and DOR 14 (95% CI: 6-32). The sROC curve for clinical PPV showed wide prediction and CI. CONCLUSIONS AND CLINICAL RELEVANCE: PPV, PVI and SVV show moderate to high diagnostic accuracy for predicting fluid responsiveness in dogs, with clinical PPV performing best. However, findings are limited by low precision and high risk of bias.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology and Pain Management, Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Buenos Aires, Argentina. Electronic address: pdonati@fvet.uba.ar.
- Department of Anesthesiology and Pain Management, Facultad de Ciencias Veterinarias, Universidad de Buenos Aires, Buenos Aires, Argentina.
- Anaesthesiology Service, Veterinary Department, Biomedical and Health Sciences Faculty, Universidad Europea de Madrid, Villaviciosa de Odón, Spain.
- Institute of General Practice, Medical Faculty of the Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
- Research Department, Universidad Hospital Italiano de Buenos Aires, Buenos Aires, Argentina.
- Department of Comparative, Diagnostic and Population Medicine, College of Veterinary Medicine, University of Florida, Gainesville, FL, USA.
Förderung
- Secretaria de Ciencia y Tecnica, Universidad de Buenos Aires
Zitieren
APA
Donati, P. A., Tarragona, L., Cordero, I. S., Franco, J. V. A., Liquitay, C. E., Portela, D. A., Araos, J., Staffieri, F., & Otero, P. E. (2026). Diagnostic accuracy of pulse pressure variation, stroke volume variation and plethysmography variability index for prediction of fluid responsiveness in anesthetized and mechanically ventilated dogs: a systematic review and meta-analysis. Veterinary Anaesthesia and Analgesia. https://doi.org/10.1016/j.vaa.2025.10.006
Vancouver
Donati PA, Tarragona L, Cordero IS, Franco JVA, Liquitay CE, Portela DA, et al. Diagnostic accuracy of pulse pressure variation, stroke volume variation and plethysmography variability index for prediction of fluid responsiveness in anesthetized and mechanically ventilated dogs: a systematic review and meta-analysis. Veterinary Anaesthesia and Analgesia. 2026. doi:10.1016/j.vaa.2025.10.006
BibTeX
@article{Donati2026,
author = {Donati, Pablo A and Tarragona, Lisa and Cordero, Ignacio Sandez and Franco, Juan V A and Liquitay, Camila Escobar and Portela, Diego A and Araos, Joaquín and Staffieri, Francesco and Otero, Pablo E},
title = {Diagnostic accuracy of pulse pressure variation, stroke volume variation and plethysmography variability index for prediction of fluid responsiveness in anesthetized and mechanically ventilated dogs: a systematic review and meta-analysis},
journal = {Veterinary Anaesthesia and Analgesia},
year = {2026},
doi = {10.1016/j.vaa.2025.10.006}
}