EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effects of tidal volume challenge on the reliability of plethysmography variability index in hepatobiliary and pancreatic surgeries: a prospective interventional study

J M Botros, Y S M Salem, M Khalil, M F Algyar, H M Yassin

Journal of Clinical Monitoring and Computing · 2023

DOI: 10.1007/s10877-023-00977-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Monitoring and Computing, 2023. Verfasst von J M Botros und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Intensive Care, Fayoum University Hospital, Fayoum University, Fayoum government, Egypt. Hauptthemen laut MEDLINE: Fluid Therapy, Respiration, Artificial. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fayoum University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The plethysmography variability index (PVI) is a non-invasive, real-time, and automated parameter for evaluating fluid responsiveness, but it does not reliably predict fluid responsiveness during low tidal volume (V T ) ventilation. We hypothesized that in a ‘tidal volume challenge’ with a transient increase in tidal volume from 6 to 8 ml Kg − 1 , the changes in PVI could predict fluid responsiveness reliably.

Method

We performed a prospective interventional study in adult patients undergoing hepatobiliary or pancreatic tumor resections and receiving controlled low V T ventilation. The values for PVI, perfusion index, stroke volume variation, and stroke volume index (SVI) were recorded at baseline V T of 6 ml Kg − 1 , 1 min after the V T challenge (8 ml Kg − 1 ), 1 min after V T 6 ml Kg − 1 reduced back again, and then 5 min after crystalloid fluid bolus 6 ml kg − 1 (actual body weight) administered over 10 min. The fluid responders were identified by SVI rise ≥ 10% after the fluid bolus.

Results

The area under the receiver operating characteristic curve for PVI value change (ΔPVI 6–8 ) after increasing V T from 6 to 8 ml Kg − 1 was 0.86 (95% confidence interval, 0.76–0.96), P < 0.001, 95% sensitivity, 68% specificity, and with best cut-off value of absolute change (ΔPVI 6–8 ) = 2.5%.

Conclusion

In hepatobiliary and pancreatic surgeries, tidal volume challenge improves the reliability of PVI for predicting fluid responsiveness and changes in PVI values obtained after tidal volume challenge are comparable to the changes in SVI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluid TherapyRespiration, ArtificialAdultHumansTidal VolumeProspective StudiesReproducibility of ResultsStroke VolumeROC CurvePlethysmographyHemodynamicsBlood Pressure

Stichwörter der Autor:innen

Fluid responsivenessLow tidal volumePlethysmography variability indexTidal volume challenge

Autor:innen und Institutionen

  • Department of Anesthesia and Intensive Care, Fayoum University Hospital, Fayoum University, Fayoum government, Egypt.
  • Department of Anesthesia and Intensive Care, Fayoum University Hospital, Fayoum University, Fayoum government, Egypt. ysm03@fayoum.edu.eg.
  • Department of Anesthesia and Intensive Care, National Liver Institute, Menoufia University, Menoufia government, Egypt.
  • Department of Anesthesiology, Surgical Intensive Care Unit and pain management, Kafrelsheikh University, Kafrelsheikh government, Egypt.

Förderung

  • Fayoum University

Zitieren

APA

Botros, J. M., Salem, Y. S. M., Khalil, M., Algyar, M. F., & Yassin, H. M. (2023). Effects of tidal volume challenge on the reliability of plethysmography variability index in hepatobiliary and pancreatic surgeries: a prospective interventional study. Journal of Clinical Monitoring and Computing. https://doi.org/10.1007/s10877-023-00977-8

Vancouver

Botros JM, Salem YSM, Khalil M, Algyar MF, Yassin HM. Effects of tidal volume challenge on the reliability of plethysmography variability index in hepatobiliary and pancreatic surgeries: a prospective interventional study. Journal of Clinical Monitoring and Computing. 2023. doi:10.1007/s10877-023-00977-8

BibTeX
@article{Botros2023,
  author = {Botros, J M and Salem, Y S M and Khalil, M and Algyar, M F and Yassin, H M},
  title = {Effects of tidal volume challenge on the reliability of plethysmography variability index in hepatobiliary and pancreatic surgeries: a prospective interventional study},
  journal = {Journal of Clinical Monitoring and Computing},
  year = {2023},
  doi = {10.1007/s10877-023-00977-8}
}
Kostenlos starten →