A novel MXene-integrated MIP-based electrochemical sensor for highly selective and sensitive lenalidomide recognition
Talanta · 2026-09 · 307 · 129809
DOI: 10.1016/j.talanta.2026.129809 ↗Kurz gefasst
Fachartikel in der Zeitschrift Talanta, 2026-09. Verfasst von Farah Elbarghathi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, A…. Hauptthemen laut MEDLINE: Electrochemical Techniques, Lenalidomide, Molecularly Imprinted Polymers, Molecular Imprinting. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Türkiye Bilimler Akademisi.
Abstract (Originalsprache)
A novel method for constructing a highly selective and sensitive MXene-supported electrochemical sensor based on MIP to detect Lenalidomide (LEN) is proposed in this study. The polymeric-coated layer was designed using ethylene glycol dimethacrylate (EGDMA) as the cross-linking agent, 2-hydroxyethyl methacrylate (HEMA) as the primary monomer, 2-hydroxy-2-methylpropiophenone as the photoinitiator, and 3-aminophenylboronic acid (3-APBA) as a functional monomer. 3-APBA introduces functional groups into the imprinting sites, facilitating specific interactions with the LEN molecule and enhancing the molecularly imprinted polymer's attachment efficiency and specificity. Electrochemical techniques, including Differential pulse voltammetry (DPV), Cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS), were employed to investigate the behaviour of the designed MIP sensor at different stages: unmodified electrode, following photo-polymerization, after removal, and rebinding processes. Moreover, the morphological characterization was performed by scanning electron microscopy (SEM) to assess the surface characteristics of the fabricated sensor. The photopolymerization (PP) technique was used to develop the 3-APBA-LEN@β-CD-Ti3C2Tx/MIP-GCE sensor; the polymer solution was polymerized on the electrode surface under UV light (365 nm). Under optimal conditions, the fabricated sensor could determine LEN in standard solutions with a linear range of 1.75 × 10-12 - 2.5 × 10-11 M. The limit of detection (LOD) and limit of quantification (LOQ) for standard solutions were 4.21 × 10-13 and 1.40 × 10-12 M, respectively. For commercial serum, pharmaceutical dosage, and tap water, the recovery ratios were calculated as 99.07%, 97.88%, and 99.12%, respectively, with mean relative standard deviations (RSDs) below 2.0%. Furthermore, in the presence of LEN analogs and other interferences, the 3-APBA-LEN@β-CD-Ti3C2Tx/MIP-GCE demonstrated exceptional sensitivity and selectivity for LEN quantification. Moreover, the signal amplification mechanism of the engineered sensor was theoretically validated through Monte Carlo-based computational simulations. Structural modeling revealed that the β-cyclodextrin (β-CD) modifier acts as a highly effective molecular trap, forming a stable host-guest inclusion functionalized MXene-LEN. This robust thermodynamic affinity and mutual structural accommodation facilitate a powerful pre-concentration effect directly at the electrode-electrolyte interface. Consequently, this specific target entrapment fundamentally explains the enhanced sensitivity and superior electrochemical performance of the functionalized MXene platform.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Ankara University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye; Ankara University, Graduate School of Health Sciences, Ankara, Türkiye.
- University of Health Sciences, Gülhane Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Türkiye. Electronic address: ahmet.cetinkya@yahoo.edu.tr.
- NecmettinErbakanUniversity, A.K. Education Faculty, Department of Science Education, Konya, Türkiye.
- Necmettin Erbakan University, Faculty of Engineering, Department of Basic Sciences, 42140, Konya, Türkiye. Electronic address: serdarakbayrak.rg@gmail.com.
- Ankara University, Stem Cell Institute, Ankara, Türkiye.
- DEVA Holding A.S., R&D Center, Tekirdağ, Türkiye; Gebze Technical University, Department of Chemistry, Kocaeli, Türkiye.
Förderung
- Türkiye Bilimler Akademisi
Zitieren
APA
Elbarghathi, F., Piskin, E., Cetinkaya, A., Zor, E., Akbayrak, S., Unal, M. A., Bellur-Atici, E., Dogan-Topal, B., & Ozkan, S. A. (2026). A novel MXene-integrated MIP-based electrochemical sensor for highly selective and sensitive lenalidomide recognition. Talanta, 307, 129809. https://doi.org/10.1016/j.talanta.2026.129809
Vancouver
Elbarghathi F, Piskin E, Cetinkaya A, Zor E, Akbayrak S, Unal MA, et al. A novel MXene-integrated MIP-based electrochemical sensor for highly selective and sensitive lenalidomide recognition. Talanta. 2026;307:129809. doi:10.1016/j.talanta.2026.129809
BibTeX
@article{Elbarghathi2026,
author = {Elbarghathi, Farah and Piskin, Ensar and Cetinkaya, Ahmet and Zor, Erhan and Akbayrak, Serdar and Unal, M Altay and Bellur-Atici, Esen and Dogan-Topal, Burcu and Ozkan, Sibel A},
title = {A novel MXene-integrated MIP-based electrochemical sensor for highly selective and sensitive lenalidomide recognition},
journal = {Talanta},
year = {2026},
volume = {307},
pages = {129809},
doi = {10.1016/j.talanta.2026.129809}
}