EUVIMEDEUVIMED entdecken
Crossref

Direct and highly sensitive impedimetric detection of creatinine in artificial urine using photopolymerized boronic-functionalized imprinted polymers films

Yujin Lee, Seok Jin Lim, Seung Hoon Lee, Jong Pil Park, Jinyoung Park

Analytica Chimica Acta · 2026

DOI: 10.1016/j.aca.2026.346330 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2026. Verfasst von Yujin Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea. Hauptthemen laut MEDLINE: Boronic Acids, Dielectric Spectroscopy, Creatinine, Molecularly Imprinted Polymers. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Korea Ministry of Education, Korea Institute for Advancement of Technology, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Highly sensitive creatinine (Cre) detection in complex urinary matrices remains challenging because of nonspecific interference and limited molecular selectivity. Here, a boronic acid-functionalized molecularly imprinted polymer (MIP) electrode was developed for label-free electrochemical impedance spectroscopy (EIS) detection of Cre in undiluted artificial urine. A Cre-imprinted film containing 4-vinylbenzeneboronic acid (4-VBBA) was photopolymerized on a vinyl-functionalized Au electrode to enhance molecular recognition. The optimized MIP electrode exhibited a linear dynamic range of 5-250 nM, a sensitivity of 0.027 nM-1, and a limit of detection (LOD) of 1.63 nM. Its sensitivity was 6.75-fold higher than that of the non-imprinted polymer (NIP). Incorporation of 4-VBBA further increased the sensitivity from 0.020 to 0.027 nM-1 and improved the selectivity coefficients from 3.12 to 5.76 to 4.49-8.57. The Cre response remained well preserved in the presence of a 10-fold excess of individual interferents. The sensor also demonstrated high fabrication reproducibility (RSD, 2.15%), operational repeatability over ten regeneration cycles (RSD, 2.67%), and analytical recoveries of 98.69-101.55%. These results establish the 4-VBBA-functionalized MIP as a robust and highly selective recognition interface for sensitive Cre sensing in complex urine-like matrices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Boronic AcidsDielectric SpectroscopyCreatinineMolecularly Imprinted PolymersMolecular ImprintingPolymersLimit of DetectionElectrodesPolymerizationHumansPhotochemical ProcessesVinyl Compounds

Stichwörter der Autor:innen

4-Vinylbenzeneboronic acidCreatinineElectrochemical impedance spectroscopyMolecularly imprinted polymerPhotopolymerization

Substanzen

Boronic AcidsCreatinineMolecularly Imprinted PolymersPolymers4-vinylphenyl boronic acidVinyl Compounds

Autor:innen und Institutionen

  • Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea.
  • School of Semiconductor Convergence Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea.
  • Department of Food Science and Technology and GreenTech-based Food Safety Research Group, BK21 Four, Chung-Ang University, Anseong, 17546, Republic of Korea. Electronic address: jppark@cau.ac.kr.
  • Department of Polymer Science & Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu, 41566, Republic of Korea; School of Semiconductor Convergence Engineering, Kyungpook National University, 80 Daeha…

Förderung

  • Korea Ministry of Education
  • Korea Institute for Advancement of Technology
  • National Research Foundation of Korea

Zitieren

APA

Lee, Y., Lim, S. J., Lee, S. H., Park, J. P., & Park, J. (2026). Direct and highly sensitive impedimetric detection of creatinine in artificial urine using photopolymerized boronic-functionalized imprinted polymers films. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2026.346330

Vancouver

Lee Y, Lim SJ, Lee SH, Park JP, Park J. Direct and highly sensitive impedimetric detection of creatinine in artificial urine using photopolymerized boronic-functionalized imprinted polymers films. Analytica Chimica Acta. 2026. doi:10.1016/j.aca.2026.346330

BibTeX
@article{Lee2026,
  author = {Lee, Yujin and Lim, Seok Jin and Lee, Seung Hoon and Park, Jong Pil and Park, Jinyoung},
  title = {Direct and highly sensitive impedimetric detection of creatinine in artificial urine using photopolymerized boronic-functionalized imprinted polymers films},
  journal = {Analytica Chimica Acta},
  year = {2026},
  doi = {10.1016/j.aca.2026.346330}
}
Kostenlos starten →