Zero Background Visualizing Phosphorescence Lateral Flow Immunoassay of Cardiac Troponin I for Rapid and Accurate Diagnosis of Myocardial Infarction
Analytical Chemistry · 18.02.2025 · 97 (6) · 3651-3660
DOI: 10.1021/acs.analchem.4c06258 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 08.02.2025. Verfasst von Qingwei Song und 8 weiteren Autor:innen. Beteiligte Einrichtung: Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China. Hauptthemen laut MEDLINE: Troponin I, Myocardial Infarction, Luminescent Measurements. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Ningbo Municipal Bureau of Science and Technology, Chinese Academy of Science and Technology Service Network Planning.
Abstract (Originalsprache)
Fluorescence lateral flow immunoassays (FL-LFIA) have attracted considerable attention in clinical diagnosis due to their outstanding merits of affordable, sensitive, on-site, and quick detection. However, they are still plagued by significant signal interference, such as autofluorescence and scattered light. The development of high-performance and robust phosphors, i.e., label probes featuring with the character of low/no optical background, remains a great challenge. Herein, we report a novel visualized phosphorescence LFIA (Phos-LFIA), where the composite microspheres, i.e., carbon dots (CDs) covalently embedded in dendritic mesoporous silicon nanoparticles (DMSNs), were designed and selected as the report probes. The obtained CDs@DMSNs revealed uniform morphologies and particle sizes, as well as ultralong (lifetime: 1.14 s, visible for over 8 s to naked eyes) room temperature phosphorescence (RTP) in aqueous solution. As competitive nanotags, CDs@DMSNs were designed for an ultralong phosphorescence-based time-gated LFIA for cardiac troponin I (cTnI) without optical interference. The fabricated Phos-LFIA test strips demonstrated zero-background signal and were applied for highly sensitive cTnI detection in both buffer and a complex serum matrix, with corresponding limits of detection (LODs) of 0.19 and 0.21 ng/mL, respectively. For a clinical validation, the proposed Phos-LFIA revealed an excellent clinical analytical performance (sensitivity: 95.45%, specificity: 88.9%, κ value: 0.85), demonstrating its potential for rapid and accurate diagnosis of myocardial infarction. This work provided a promising background-free probe for FL-LFIA, and it would also open an opportunity for developing highly sensitive screening platforms for other targets through modifying different recognition ligands onto CDs@DMSNs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, P. R. China.
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China.
- Department of Clinical Laboratory, The First Affiliated Hospital of Ningbo University, Ningbo 315010, P. R. China.
ORCID-Profile: Sihua Qian, Jianping Zheng, Kaizhe Wang, Yuhui Wang
Förderung
- National Key Research and Development Program of China
- Ningbo Municipal Bureau of Science and Technology
- Chinese Academy of Science and Technology Service Network Planning
- National Natural Science Foundation of China
Zitieren
APA
Song, Q., Liao, Z., Zheng, L., Fu, P., Qian, S., Liang, W., Zheng, J., Wang, K., & Wang, Y. (2025). Zero Background Visualizing Phosphorescence Lateral Flow Immunoassay of Cardiac Troponin I for Rapid and Accurate Diagnosis of Myocardial Infarction. Analytical Chemistry, 97(6), 3651-3660. https://doi.org/10.1021/acs.analchem.4c06258
Vancouver
Song Q, Liao Z, Zheng L, Fu P, Qian S, Liang W, et al. Zero Background Visualizing Phosphorescence Lateral Flow Immunoassay of Cardiac Troponin I for Rapid and Accurate Diagnosis of Myocardial Infarction. Analytical Chemistry. 2025;97(6):3651-3660. doi:10.1021/acs.analchem.4c06258
BibTeX
@article{Song2025,
author = {Song, Qingwei and Liao, Zixuan and Zheng, Lin and Fu, Pan and Qian, Sihua and Liang, Wei and Zheng, Jianping and Wang, Kaizhe and Wang, Yuhui},
title = {Zero Background Visualizing Phosphorescence Lateral Flow Immunoassay of Cardiac Troponin I for Rapid and Accurate Diagnosis of Myocardial Infarction},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {6},
pages = {3651--3660},
doi = {10.1021/acs.analchem.4c06258}
}
EUVIMED