EUVIMEDEUVIMED entdecken
Crossref

Qualitative and quantitative detection of glucose, uric acid, and cholesterol in rat skin interstitial fluid by a porous microneedle

Geng Zhu, Yang Wang, Xi Yang, Miaomiao Li, Cheng Chen, Xiaoyi Lv, Hui Zhang, Jinliang Sheng, Yan Huang, Xiangwei Zhao

Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy · 2027

DOI: 10.1016/j.saa.2026.128654 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2027. Verfasst von Geng Zhu und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing 211189, China;…. Hauptthemen laut MEDLINE: Cholesterol, Glucose, Uric Acid, Needles. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Shenzen Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With their increasing incidence, metabolic diseases have already become a significant health problem. A porous microneedle was fabricated for qualitative colorimetric and quantitative surface-enhanced Raman scattering (SERS) detection of glucose, uric acid, and cholesterol. The skin interstitial fluid containing glucose, uric acid, and cholesterol was collected by the porous microneedle with minimal invasion, and then the three biomolecules were converted into hydrogen peroxide by their corresponding oxidases. Hydrogen peroxide reacted with 3,3',5,5'-tetramethylbenzidine (TMB) to form a colored substrate for qualitative detection, and it reacted with 4-mercaptophenylboronic acid (4-MPBA) on SERS probes for quantitative detection. For glucose, colorimetric detection can be used at concentrations below 5 mM, and SERS detection can be applied in the 5-20 mM range. For uric acid, colorimetric detection is suitable at concentrations below 0.6 mM, while SERS detection can be used in the 0.6-0.9 mM range. For cholesterol, colorimetric detection is applicable below 6 mM, and SERS detection can be employed in the 6-9 mM range. The developed porous microneedles would be a tool for graded diagnosis of metabolic syndrome in home testing and community testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CholesterolGlucoseUric AcidNeedlesExtracellular FluidSkinAnimalsSpectrum Analysis, RamanPorosityRatsColorimetry

Stichwörter der Autor:innen

A porous microneedleCholesterolDual-mode detectionGlucoseSkin interstitial fluidUric acid

Substanzen

CholesterolGlucoseUric Acid

Autor:innen und Institutionen

  • State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing 211189, China; Southeast University Shenzhen Research Institute, Shenzhen, 518000, C…
  • State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing 211189, China.
  • State International Joint Research Center for Animal Health Breeding, College of Animal Science and Technology, Shihezi University, Shihezi 832003, China.
  • College of Software, Xinjiang University, Urumqi 830046, China.
  • State International Joint Research Center for Animal Health Breeding, College of Animal Science and Technology, Shihezi University, Shihezi 832003, China. Electronic address: sjlshz@126.com.
  • State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing 211189, China. Electronic address: hylucky@seu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Planning Project of Shenzen Municipality

Zitieren

APA

Zhu, G., Wang, Y., Yang, X., Li, M., Chen, C., Lv, X., Zhang, H., Sheng, J., Huang, Y., & Zhao, X. (2027). Qualitative and quantitative detection of glucose, uric acid, and cholesterol in rat skin interstitial fluid by a porous microneedle. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. https://doi.org/10.1016/j.saa.2026.128654

Vancouver

Zhu G, Wang Y, Yang X, Li M, Chen C, Lv X, et al. Qualitative and quantitative detection of glucose, uric acid, and cholesterol in rat skin interstitial fluid by a porous microneedle. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy. 2027. doi:10.1016/j.saa.2026.128654

BibTeX
@article{Zhu2027,
  author = {Zhu, Geng and Wang, Yang and Yang, Xi and Li, Miaomiao and Chen, Cheng and Lv, Xiaoyi and Zhang, Hui and Sheng, Jinliang and Huang, Yan and Zhao, Xiangwei},
  title = {Qualitative and quantitative detection of glucose, uric acid, and cholesterol in rat skin interstitial fluid by a porous microneedle},
  journal = {Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy},
  year = {2027},
  doi = {10.1016/j.saa.2026.128654}
}
Kostenlos starten →