A porous SERS microneedle for multiplex detection of glucose, uric acid, and cholesterol in interstitial fluid

Geng Zhu, Yang Wang, Xi Yang, Cheng Chen, Xiaoyi Lv, Yan Huang, Xiangwei Zhao

Analytica Chimica Acta · 2025-12 · 1380 · 344788

DOI: 10.1016/j.aca.2025.344788 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytica Chimica Acta, 2025-12. Verfasst von Geng Zhu und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 211189, China. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Cholesterol, Uric Acid, Glucose. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Science and Technology Planning Project of Shenzen Municipality, Urumqi Science and Technology Bureau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To detect glucose, uric acid and cholesterol in interstitial fluid simultaneously for prognosis of metabolic syndrome (MetS), a porous surface-enhanced Raman scattering (SERS) microneedle was fabricated by integrating SERS probes and three kinds of enzyme in three independent areas of one porous microneedle, respectively. Paraffin wax was used as a hydrophobic barrier to segment a porous microneedle to three independent areas, in which gold nanoshells (used as SERS substrates), 4-mercaptophenylboronic acid (4-MPBA), and one of glucose oxidase, urate oxidase, and cholesterol oxidase were integrated, respectively, and thus SERS probes altered SERS signals under the action of enzymes on their substrates. In vitro experiments demonstrated stable and accurate detection within the ranges of 0-15 mM glucose, 0-0.9 mM uric acid, and 0-9 mM cholesterol. Animal studies confirmed its feasibility for in vivo use. This porous SERS microneedle offers a minimally invasive and convenient solution for multiplex detection and point-of-care diagnosis in patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrum Analysis, RamanCholesterolUric AcidGlucoseNeedlesExtracellular FluidPorosityAnimalsGoldMiceSurface PropertiesBoronic AcidsSulfhydryl Compounds

Stichwörter der Autor:innen

CholesterolGlucoseInterstitial fluidPorous SERS microneedlesSurface-enhanced Raman scatteringUric acid

Substanzen

CholesterolUric AcidGlucoseGold4-mercaptophenylboronic acidBoronic AcidsSulfhydryl Compounds

Autor:innen und Institutionen

  • State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 211189, China.
  • College of Software, Xinjiang University, Urumqi, 830046, China.
  • State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 211189, China. Electronic address: hyluchy@seu.edu.cn.
  • State Key Laboratory of Digital Medical Engineering, School of Biological Science & Medical Engineering, Southeast University, Nanjing, 211189, China; State International Joint Research Center for Animal Health Breeding…

Förderung

  • National Natural Science Foundation of China
  • Science and Technology Planning Project of Shenzen Municipality
  • Urumqi Science and Technology Bureau

Zitieren

APA

Zhu, G., Wang, Y., Yang, X., Chen, C., Lv, X., Huang, Y., & Zhao, X. (2025). A porous SERS microneedle for multiplex detection of glucose, uric acid, and cholesterol in interstitial fluid. Analytica Chimica Acta, 1380, 344788. https://doi.org/10.1016/j.aca.2025.344788

Vancouver

Zhu G, Wang Y, Yang X, Chen C, Lv X, Huang Y, et al. A porous SERS microneedle for multiplex detection of glucose, uric acid, and cholesterol in interstitial fluid. Analytica Chimica Acta. 2025;1380:344788. doi:10.1016/j.aca.2025.344788

BibTeX
@article{Zhu2025,
  author = {Zhu, Geng and Wang, Yang and Yang, Xi and Chen, Cheng and Lv, Xiaoyi and Huang, Yan and Zhao, Xiangwei},
  title = {A porous SERS microneedle for multiplex detection of glucose, uric acid, and cholesterol in interstitial fluid},
  journal = {Analytica Chimica Acta},
  year = {2025},
  volume = {1380},
  pages = {344788},
  doi = {10.1016/j.aca.2025.344788}
}
Kostenlos starten →