Advanced monitoring of TOF+PSF reconstruction performance in digital PET/CT: Clinical implications from the uMI 550 evaluation
Radiography · 2025-10 · 31 (6) · 103192
DOI: 10.1016/j.radi.2025.103192 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiography, 2025-10. Verfasst von M El Kafhali und 6 weiteren Autor:innen. Beteiligte Einrichtung: Moulay Ismail University, Faculty of Sciences, Physical Sciences and Engineering, Innovative Research and Applied Physics (IRAP), Meknes, Morocco. El…. Hauptthemen laut MEDLINE: Positron Emission Tomography Computed Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Advancements in digital PET/CT technology have enabled more precise quantification and image quality optimization. This study evaluated the reconstruction performance of the uMI 550 digital PET/CT system using standardized phantoms, focusing on reconstruction algorithms incorporating Time-of-Flight (TOF) and Point Spread Function (PSF) modeling. Unlike prior uMI 550 evaluations, this study integrates uncertainty-based analysis and longitudinal QC correlations to determine optimal reconstruction conditions. METHODS: Performance assessments followed NEMA NU 2-2007 protocols with a NEMA IEC image quality phantom and QC phantoms. The analysis examined contrast recovery, image noise, and standardized uptake value (SUV) metrics (SUVmax (single hottest voxel), SUVmean (average uptake in a region), and SUVpeak (average uptake within a fixed 1 cm3 around the hottest area)), under varying reconstruction settings, with integration of uncertainty modeling and quality-control (QC) correlations. Count-rate performance was assessed using Noise Equivalent Count Rate (NECR) and true count rate. RESULTS: Contrast recovery rose from 89.1 % at iteration 1-152.2 % at iteration 4, after which further iterations increased noise without added benefit. SUVmean remained stable (1.01 ± 0.03), SUVpeak converged rapidly with minimal sensitivity to reconstruction, while SUVmax overshot to 1.34 by iteration 6 due to edge artifacts. Count-rate analysis showed peak NECR at 17.2 kBq/mL and maximum true count rate of 479.4 kcps at 26.3 kBq/mL, with quantification errors consistently below 5 %. Correlation analysis (r > 0.85) identified SUVpeak, SUVmean, NECR, and contrast recovery as the most influential QC parameters. CONCLUSION: SUVpeak emerged as the most robust quantitative biomarker, providing practical guidance for protocol optimization, harmonized PET/CT workflows, and long-term system monitoring. IMPLICATIONS FOR PRACTICE: Adopting evidence-based reconstruction strategies and consistent QC can improve diagnostic confidence and standardization in clinical PET/CT imaging.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Moulay Ismail University, Faculty of Sciences, Physical Sciences and Engineering, Innovative Research and Applied Physics (IRAP), Meknes, Morocco. Electronic address: m.elkafhali@edu.umi.ac.ma.
- Department of Radiologic Technology, School of Allied Medical Sciences, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.
- Labratory of Solid-State Physics, Department of Physics, Faculty of Science Dhar El Mahraz, sidi Mohamed Ben Abellal University, Fez, Morocco.
- Moulay Ismail University, Faculty of Sciences, Physical Sciences and Engineering, Innovative Research and Applied Physics (IRAP), Meknes, Morocco.
- High Energy Physics Laboratory - Modeling and Simulation (HEPL-MS), Faculty of Sciences, Department of Physics, Mohammed V University, Rabat, Morocco.
- GHANDI Medical Imaging Center - Casablanca, Morocco.
Zitieren
APA
El Kafhali, M., Tahmasbi, M., Rahmouni, A., Khalis, M., El Moutaoukkil, A., Sebihi, R., & El Kessioui, A. (2025). Advanced monitoring of TOF+PSF reconstruction performance in digital PET/CT: Clinical implications from the uMI 550 evaluation. Radiography, 31(6), 103192. https://doi.org/10.1016/j.radi.2025.103192
Vancouver
El Kafhali M, Tahmasbi M, Rahmouni A, Khalis M, El Moutaoukkil A, Sebihi R, et al. Advanced monitoring of TOF+PSF reconstruction performance in digital PET/CT: Clinical implications from the uMI 550 evaluation. Radiography. 2025;31(6):103192. doi:10.1016/j.radi.2025.103192
BibTeX
@article{ElKafhali2025,
author = {El Kafhali, M and Tahmasbi, M and Rahmouni, A and Khalis, M and El Moutaoukkil, A and Sebihi, R and El Kessioui, A},
title = {Advanced monitoring of TOF+PSF reconstruction performance in digital PET/CT: Clinical implications from the uMI 550 evaluation},
journal = {Radiography},
year = {2025},
volume = {31},
number = {6},
pages = {103192},
doi = {10.1016/j.radi.2025.103192}
}
EUVIMED