Comparative accuracy study of three extraoral photogrammetry methods, one intraoral photogrammetry system, and a noncalibrated implant scan body technique
The Journal of Prosthetic Dentistry · 2026-07 · 136 (1) · 267-274
DOI: 10.1016/j.prosdent.2026.01.010 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-07. Verfasst von Marta Revilla-León und 5 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Photogrammetry, Dental Implants. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 41 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The accuracy of implant scans is contingent upon the scanning technique selected. The accuracy of complete arch implant scans using different techniques, including intraoral and extraoral photogrammetry methods (PGs) and noncalibrated implant scan bodies (ISBs) oriented toward the center of the arch, requires further evaluation. PURPOSE: The purpose of this in vitro study was to evaluate the accuracy of complete arch implant scans captured using 3 extraoral PGs, 1 intraoral PG, and 1 noncalibrated ISB system. MATERIAL AND METHODS: An edentulous stone cast with 6 implant abutment analogs and a laboratory scan (T710) for the control scan were obtained. Five groups were created based on the technique used to capture complete arch implant scans: 3 extraoral PG systems, Grammee (Grammee group), MicronMapper with screw-retained markers (MM-Screw group), and MicronMapper with snap-on markers (MM-Snap group), an intraoral PG (Elite group), and a noncalibrated ISB system (IOConnect group) (n=15). In the 3 extraoral PG groups, the corresponding markers were placed on the implant abutments of the reference cast, followed by the recording of consecutive implant scans with the specific camera of each system. In the Elite group, the ISBs were placed on the implant abutments of the reference cast, and scans were captured using the explicit intraoral scanner (IOS) (Aoralscan Elite). In the IOConnect group, the noncalibrated ISBs were placed on the implant abutments toward the center of the arch. Then, IOS scans were captured using an IOS (TRIOS 5). Euclidean linear and angular measurements were calculated for the 6 implants. The measurements obtained in the reference scan were used to calculate the scanning discrepancies with each experimental scan. One-way ANOVA and Tukey post hoc tests were used to analyze trueness. The Levene test was used to analyze precision (α=.05). RESULTS: Linear (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director of Research and Digital Dentistry, Kois Ce…
- Associate Professor, Department of Dental Orthodontics, Faculty of Medicine and Health Sciences, Catholic University of Valencia (UCV), Valencia, Spain.
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
- Private practice, Valparaiso, Ind.
- Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practice, Seattle,…
- Adjunct Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
Zitieren
APA
Revilla-León, M., Guinot-Barona, C., Barmak, A. B., Drone, M., Kois, J. C., & Pérez-Barquero, J. A. (2026). Comparative accuracy study of three extraoral photogrammetry methods, one intraoral photogrammetry system, and a noncalibrated implant scan body technique. The Journal of Prosthetic Dentistry, 136(1), 267-274. https://doi.org/10.1016/j.prosdent.2026.01.010
Vancouver
Revilla-León M, Guinot-Barona C, Barmak AB, Drone M, Kois JC, Pérez-Barquero JA. Comparative accuracy study of three extraoral photogrammetry methods, one intraoral photogrammetry system, and a noncalibrated implant scan body technique. The Journal of Prosthetic Dentistry. 2026;136(1):267-274. doi:10.1016/j.prosdent.2026.01.010
BibTeX
@article{RevillaLen2026,
author = {Revilla-León, Marta and Guinot-Barona, Clara and Barmak, Abdul B and Drone, Michael and Kois, John C and Pérez-Barquero, Jorge Alonso},
title = {Comparative accuracy study of three extraoral photogrammetry methods, one intraoral photogrammetry system, and a noncalibrated implant scan body technique},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {136},
number = {1},
pages = {267--274},
doi = {10.1016/j.prosdent.2026.01.010}
}
EUVIMED