Influence of denture fabrication methods on trueness, number of photograms, and scanning time in extraoral digitization of maxillary complete denture with an intraoral scanner
The Journal of Prosthetic Dentistry · 2026
DOI: 10.1016/j.prosdent.2026.04.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026. Verfasst von Nareudee Limpuangthip und 2 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand. Hauptthemen laut MEDLINE: Denture Design, Denture, Complete, Upper, Computer-Aided Design. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Research Foundation of Korea, Chulalongkorn University Faculty of Dentistry.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Denture duplication is often necessary to simplify new denture fabrication. The accuracy of extraoral digitization of dentures using an intraoral scanner (IOS) may be influenced by differences in material properties and surface textures among dentures fabricated using different methods. However, research examining this effect remains limited. PURPOSE: The purpose of this in vitro study was to evaluate the influence of different denture fabrication methods on the trueness in the extraoral digitization of maxillary complete dentures with an IOS. The number of photograms and the scanning time were also assessed. MATERIAL AND METHODS: Three types of maxillary complete dentures classified by their fabrication methods were evaluated: metal-based heat-polymerized polymethyl methacrylate (PMMA) and prefabricated PMMA teeth, milled PMMA denture base and milled teeth, and 3-dimensionally (3D) printed denture base and 3D printed teeth. Scan powder was applied only to the metal surfaces of the heat-polymerized denture. Each denture was digitized using a desktop scanner (reference) and an IOS (n=10 per group). Trueness was analyzed using a 3D inspection software program for the whole denture, denture base, and tooth components. The number of photograms and scanning time were recorded. Data were analyzed using analysis of variance and the Kruskal-Wallis test (α=.05). RESULTS: The milled denture showed the highest root mean square (RMS) deviations (µm) for the whole denture (118 ±7) and denture base (139 ±9), followed by the metal-based group (95 ±6 and 108 ±8), with the 3D printed group demonstrating the lowest deviations (62 ±4 and 68 ±7) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
- Graduate student, Department of Prosthodontics, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand.
- Associate Professor, Department of Prosthodontics and Dental Research Institute, Seoul National University School of Dentistry, Seoul, Republic of Korea. Electronic address: jaehyun.lee@snu.ac.kr.
Förderung
- National Research Foundation of Korea
- Chulalongkorn University Faculty of Dentistry
Zitieren
APA
Limpuangthip, N., Tanvarasethee, V., & Lee, J. H. (2026). Influence of denture fabrication methods on trueness, number of photograms, and scanning time in extraoral digitization of maxillary complete denture with an intraoral scanner. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.04.004
Vancouver
Limpuangthip N, Tanvarasethee V, Lee JH. Influence of denture fabrication methods on trueness, number of photograms, and scanning time in extraoral digitization of maxillary complete denture with an intraoral scanner. The Journal of Prosthetic Dentistry. 2026. doi:10.1016/j.prosdent.2026.04.004
BibTeX
@article{Limpuangthip2026,
author = {Limpuangthip, Nareudee and Tanvarasethee, Veerit and Lee, Jae-Hyun},
title = {Influence of denture fabrication methods on trueness, number of photograms, and scanning time in extraoral digitization of maxillary complete denture with an intraoral scanner},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
doi = {10.1016/j.prosdent.2026.04.004}
}
EUVIMED