Agreement between digitally predicted and clinically verified occlusal contacts in computer-aided design and computer-aided manufacture (CAD-CAM) occlusal devices: A cross-sectional study

Marcelo José Palma-Fernandes, Júlio Ruiz-Marrara, Maria Fernanda de Campos-Muller, Maria Amália Dias Pereira Calças, Caio Sberni Pinheiro de Souza, Victor Hugo Alves Ribeiro-Silva, Rodrigo Galo, Inês Sansonetty Gonçalves Côrte-Real, Jardel Francisco Mazzi-Chaves, Laís Valencise Magri

The Journal of Prosthetic Dentistry · 2026-07 · 136 (1) · 250-257

DOI: 10.1016/j.prosdent.2026.01.030 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-07. Verfasst von Marcelo José Palma-Fernandes und 9 weiteren Autor:innen. Beteiligte Einrichtung: Master's student, Faculty of Dental Medicine, University of Porto, Porto, Portugal. Hauptthemen laut MEDLINE: Computer-Aided Design, Dental Prosthesis Design, Dental Occlusion. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: The growing adoption of digital workflows and artificial intelligence (AI)-assisted design has revolutionized occlusal device fabrication, offering improved precision, efficiency, and reproducibility. However, the clinical reliability of digitally predicted occlusal contacts, particularly across different intensity levels and anatomic regions, remains insufficiently validated. PURPOSE: This study aimed to evaluate the accuracy and reliability of AI-predicted occlusal contacts in computer-aided design and computer-aided manufacture (CAD-CAM) occlusal devices fabricated through a fully digital workflow, with comparisons stratified by contact intensity and anatomic region. MATERIAL AND METHODS: A cross-sectional observational study was conducted with 53 occlusal devices (45 maxillary, 8 mandibular) fabricated using intraoral scanning, AI-based CAD software program (Medit Link v3.2.2; Medit), and 3-dimensional (3D) printing. Predicted occlusal contacts were automatically generated by the software program and compared with clinical markings obtained using articulating paper during the initial adjustment session. Agreement rates were calculated by contact intensity (low, medium, high) and anatomic region (anterior, posterior). Statistical analyses included descriptive statistics, the Friedman test for repeated-measures comparisons across intensity levels, Bonferroni-adjusted post hoc tests, and intraclass correlation coefficients [ICC(2,1)] to assess internal consistency among continuous measurements within each device (α=.05). RESULTS: Agreement between digitally predicted and clinically verified contacts increased systematically with intensity, with mean coincidence rates of 59.4%, 69.7%, and 79% for low-, medium-, and high-intensity contacts, respectively. Low-intensity contacts showed the greatest dispersion, while high-intensity contacts displayed the most stable agreement values. Internal consistency among the 3 continuous agreement measurements was supported by ICC(2,1) values ranging from 0.797 to 0.867. Region-specific analyses demonstrated clearer separation among intensity levels in the anterior region, whereas medium- and high-intensity contacts overlapped more extensively in the posterior region. CONCLUSIONS: AI-assisted CAD-CAM workflows demonstrated progressively higher predictive accuracy as occlusal contact intensity increased, with high-intensity contacts showing the most consistent correspondence with clinical markings. In contrast, the reduced accuracy and greater variability observed for low-intensity contacts-particularly in posterior regions-underscore the continued necessity of clinical verification during device adjustment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignDental Prosthesis DesignDental OcclusionHumansCross-Sectional StudiesArtificial IntelligenceReproducibility of ResultsSoftwarePrinting, Three-DimensionalWorkflowImaging, Three-Dimensional

Autor:innen und Institutionen

  • Master's student, Faculty of Dental Medicine, University of Porto, Porto, Portugal.
  • PhD student, Faculty of Dental Medicine, University of Porto, Porto, Portugal; Department of Prosthodontics and Dental Materials, School of Dentistry of Ribeirão Preto, University of São Paulom (USP), Ribeirão Preto, Sã…
  • Predoctoral student, Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • Master's student, Department of Restorative Dentistry, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.
  • Associated Professor, Department of Prosthodontics and Dental Materials, School of Dentistry of Ribeirão Preto, University of São Paulo (USP), Ribeirão Preto, São Paulo, Brazil.
  • Associated Professor, Faculty of Dental Medicine, University of Porto, Porto, Portugal.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Palma-Fernandes, M. J., Ruiz-Marrara, J., de Campos-Muller, M. F., Calças, M. A. D. P., Souza, C. S. P., Ribeiro-Silva, V. H. A., Galo, R., Côrte-Real, I. S. G., Mazzi-Chaves, J. F., & Magri, L. V. (2026). Agreement between digitally predicted and clinically verified occlusal contacts in computer-aided design and computer-aided manufacture (CAD-CAM) occlusal devices: A cross-sectional study. The Journal of Prosthetic Dentistry, 136(1), 250-257. https://doi.org/10.1016/j.prosdent.2026.01.030

Vancouver

Palma-Fernandes MJ, Ruiz-Marrara J, de Campos-Muller MF, Calças MADP, Souza CSP, Ribeiro-Silva VHA, et al. Agreement between digitally predicted and clinically verified occlusal contacts in computer-aided design and computer-aided manufacture (CAD-CAM) occlusal devices: A cross-sectional study. The Journal of Prosthetic Dentistry. 2026;136(1):250-257. doi:10.1016/j.prosdent.2026.01.030

BibTeX
@article{PalmaFernandes2026,
  author = {Palma-Fernandes, Marcelo José and Ruiz-Marrara, Júlio and de Campos-Muller, Maria Fernanda and Calças, Maria Amália Dias Pereira and Souza, Caio Sberni Pinheiro de and Ribeiro-Silva, Victor Hugo Alves and Galo, Rodrigo and Côrte-Real, Inês Sansonetty Gonçalves and Mazzi-Chaves, Jardel Francisco and Magri, Laís Valencise},
  title = {Agreement between digitally predicted and clinically verified occlusal contacts in computer-aided design and computer-aided manufacture (CAD-CAM) occlusal devices: A cross-sectional study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2026},
  volume = {136},
  number = {1},
  pages = {250--257},
  doi = {10.1016/j.prosdent.2026.01.030}
}
Kostenlos starten →