Influence of anti-aliasing and pixel offset slicing parameters on dimensional accuracy and surface characteristics of digital light processing printed monolithic zirconia crowns: An in vitro study
The Journal of Prosthetic Dentistry · 2026-07 · 136 (1) · e225-e236
DOI: 10.1016/j.prosdent.2026.03.008 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-07. Verfasst von KeunBaDa Son und 7 weiteren Autor:innen. Beteiligte Einrichtung: Research Professor, Advanced Dental Device Development Institute, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea. Hauptthemen laut MEDLINE: Crowns, Zirconium, Computer-Aided Design, Dental Prosthesis Design. Die Arbeit nennt 45 Literaturangaben. Gefördert von: Technology Development, National Research Foundation of Korea, Ministry of Trade, Industry and Energy.
Abstract (Originalsprache)
STATEMENT OF PROBLEM Software-controlled slicing parameters such as anti-aliasing and pixel offset have been widely implemented in digital light processing (DLP) 3-dimensional (3D) printers, but their effects on the fit accuracy and surface quality of additively manufactured zirconia crowns remain insufficiently characterized. PURPOSE The purpose of this in vitro study was to evaluate the effects of anti-aliasing level and pixel offset on the marginal and internal adaptation, surface trueness, and surface roughness of monolithic zirconia crowns fabricated by DLP 3D printing. MATERIAL AND METHODS A prepared maxillary right first molar in a typodont model was digitized and used to design a monolithic zirconia crown with standardized computer-aided design (CAD) parameters (relief for luting agent 50 µm, marginal gap 0 µm). Crowns were fabricated from a zirconia suspension using a DLP printer under 9 slicing conditions combining 3 anti-aliasing levels (high, medium, zero) and 3 pixel offsets (+1, 0, -1 pixel). In total, 135 crowns were produced (n=15 per group) and sintered according to the manufacturer's protocol. Marginal, axial, and occlusal gaps were quantified as the root mean square deviation (RMSD) between the seated crown and the preparation scan. Surface trueness was calculated as the RMSD between the scanned crown and the CAD model, and surface roughness (Ra, Rz, Rq) at the marginal and cusp regions was measured using a confocal laser scanning microscope. Data were analyzed using 1- and 2-way analysis of variance, multivariate analysis of variance, and multiple linear regression (α=.05). RESULTS Marginal gaps ranged from 89.7 to 96.1 µm across all anti-aliasing and pixel offset conditions, with no significant differences among groups (P>.05). Internal adaptation was significantly influenced by both parameters: medium anti-aliasing and a +1 pixel offset yielded the smallest axial gaps, whereas a -1 pixel offset yielded the smallest occlusal gaps (P .05). CONCLUSIONS All slicing parameter combinations produced marginal gaps below 100 µm. A high anti-aliasing level combined with a -1 pixel offset provided the most favorable balance among internal adaptation, surface trueness, and surface roughness within clinically acceptable limits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Research Professor, Advanced Dental Device Development Institute, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
- Postdoctoral Researcher, Advanced Dental Device Development Institute, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea; Assistant Professor, Department of Dental Technology, Dongnam Health U…
- Principal Engineer, 3D Controls Co. Ltd., Gangseo-gu, Busan, Republic of Korea.
- Director, Institute of Advanced Convergence Technology, Kyungpook National University, Daegu, Republic of Korea.
- Professor, School of Electronics Engineering, Kyungpook National University, Daegu, Republic of Korea.
- Professor, Department of Pediatric Dentistry, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea.
Förderung
- Technology Development
- National Research Foundation of Korea
- Ministry of Trade, Industry and Energy
- Ministry of Science and ICT, South Korea
Zitieren
APA
Son, K., Lee, J. M., Jang, K. J., Hwang, J. H., Lee, J. H., Kim, H. D., Lee, J., & Lee, K. B. (2026). Influence of anti-aliasing and pixel offset slicing parameters on dimensional accuracy and surface characteristics of digital light processing printed monolithic zirconia crowns: An in vitro study. The Journal of Prosthetic Dentistry, 136(1), e225-e236. https://doi.org/10.1016/j.prosdent.2026.03.008
Vancouver
Son K, Lee JM, Jang KJ, Hwang JH, Lee JH, Kim HD, et al. Influence of anti-aliasing and pixel offset slicing parameters on dimensional accuracy and surface characteristics of digital light processing printed monolithic zirconia crowns: An in vitro study. The Journal of Prosthetic Dentistry. 2026;136(1):e225-e236. doi:10.1016/j.prosdent.2026.03.008
BibTeX
@article{Son2026,
author = {Son, KeunBaDa and Lee, Ji-Min and Jang, Kyoung-Jun and Hwang, Jun Ho and Lee, Jong Hoon and Kim, Hyun Deok and Lee, Jaesik and Lee, Kyu-Bok},
title = {Influence of anti-aliasing and pixel offset slicing parameters on dimensional accuracy and surface characteristics of digital light processing printed monolithic zirconia crowns: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {136},
number = {1},
pages = {e225--e236},
doi = {10.1016/j.prosdent.2026.03.008}
}
EUVIMED