Influence of different scan body design features and intraoral scanners on the congruence between scan body meshes and library files: An in vitro study
The Journal of Prosthetic Dentistry · 2024-08 · 132 (2) · 454.e1-454.e11
DOI: 10.1016/j.prosdent.2024.05.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-08. Verfasst von George Michelinakis und 3 weiteren Autor:innen. Beteiligte Einrichtung: Private practice, Heraklion, Greece. Electronic address: gmichelinakis@hotmail.com. Hauptthemen laut MEDLINE: Computer-Aided Design, Printing, Three-Dimensional. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 47 Literaturangaben.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Implant scan bodies (ISBs) present with a variety of features, including diverse design geometries and manufacturing materials. How these features influence the congruence between the clinically obtained mesh file and the software-based library file of the scan body during the alignment stage within the computer-aided design (CAD) software program is unclear. It is also uncertain how these features influence the scanning accuracy of different scanners. PURPOSE: The purpose of this in vitro study was to investigate how various scan body shapes manufactured from different materials influence the scanning accuracy of 6 intraoral scanners (IOSs) and 1 desktop scanner. MATERIAL AND METHODS: A 3-dimensionally (3D) printed cast fitted with 4 different implant analogs and their corresponding scan bodies (Straumann Cares RN Mono; Straumann, MIS V3 SP; MIS, Paltop SP; Paltop and TV70; TRI) was scanned using 6 intraoral scanners (Primescan; Dentsply Sirona, TRIOS 3; 3Shape A/S, TRIOS 5; 3Shape A/S, Medit i-700; Medit, Fussen S6000; Fussen, and Runyes 3DS; Runyes) and 1 desktop scanner (7series; Dental Wings). A metrology mesh comparison software program was used for analysis. Inferences were drawn using a univariate repeated measures 2-way ANOVA. Post hoc analysis was conducted with pairwise Bonferroni tests (α=.05). RESULTS: A significant 2-way interaction was found between scanner model and scan body model, (F [5.518, 49.659]=36.251, P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Private practice, Heraklion, Greece. Electronic address: gmichelinakis@hotmail.com.
- Private practice, Heraklion, Greece.
- Private practice, Athens, Greece.
Zitieren
APA
Michelinakis, G., Apostolakis, D., Nikolidakis, D., & Lapsanis, G. (2024). Influence of different scan body design features and intraoral scanners on the congruence between scan body meshes and library files: An in vitro study. The Journal of Prosthetic Dentistry, 132(2), 454.e1-454.e11. https://doi.org/10.1016/j.prosdent.2024.05.016
Vancouver
Michelinakis G, Apostolakis D, Nikolidakis D, Lapsanis G. Influence of different scan body design features and intraoral scanners on the congruence between scan body meshes and library files: An in vitro study. The Journal of Prosthetic Dentistry. 2024;132(2):454.e1-454.e11. doi:10.1016/j.prosdent.2024.05.016
BibTeX
@article{Michelinakis2024,
author = {Michelinakis, George and Apostolakis, Dimitrios and Nikolidakis, Dimitrios and Lapsanis, George},
title = {Influence of different scan body design features and intraoral scanners on the congruence between scan body meshes and library files: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {132},
number = {2},
pages = {454.e1--454.e11},
doi = {10.1016/j.prosdent.2024.05.016}
}
EUVIMED