Accuracy of autonomous dental implant robotic system versus static guide-assisted implant surgery in immediate implant placement: A retrospective clinical study
The Journal of Prosthetic Dentistry · 2026-04 · 135 (4) · 771-776
DOI: 10.1016/j.prosdent.2025.06.038 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2026-04. Verfasst von Xuehan Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate student, Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, PR China; and Postgraduate student, Or…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Dental Arch, Surgery, Computer-Assisted, Dental Implantation, Endosseous. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Shandong Province Natural Science Foundation.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: The success rate of implant surgery depends on the accuracy, influenced by the skill and experience of the surgeon. Even an experienced surgeon may achieve varying results under different conditions. In addition, the anatomic shape of the alveolar fossa after tooth extraction requires a higher level of accuracy. PURPOSE: The purpose of this retrospective clinical study was to compare the accuracy in immediate implant placement between an autonomous dental implant robotic system (ADIRS) and static computer-assisted implant surgery (s-CAIS) to evaluate their clinical application value. The comparison provided a basis for the clinical application of ADIRS in immediate implant placement. MATERIAL AND METHODS: This retrospective study included 22 patients with a total of 49 implants that underwent immediate implant placement with ADIRS versus s-CAIS. The ADIRS group was divided into 2 subgroups, one with n≤2 simultaneous implants and the other with n≥5 simultaneous implants. The simultaneous placement of implants was located in the same arch. Coronal deviation, apical deviation, and angular deviation were analyzed by comparing preoperative and postoperative cone beam computed tomography (CBCT) scans to assess the differences in accuracy between groups. The Mann Whitney U test and Welch t test were used to assess the statistical significance of results (α=.05). RESULTS: The median (interquartile range) of coronal deviation, apical deviation, and angular deviation in the ADIRS group were 0.30 (0.10) mm, 0.33 (0.15) mm, and 0.68 (0.23) degrees, versus 0.88 (0.98) mm, 1.62 (0.94) mm, and 4.29 (2.51) degrees in the s-CAIS group, with significantly higher accuracy in the ADIRS group (P .05). CONCLUSIONS: ADIRS demonstrated better accuracy compared with s-CAIS in immediate implant placement, and the number of implants placed at the same time in the ADIRS group had no significant effect on implant accuracy, suggesting its potential for routine clinical use. However, further research is needed to address potential challenges before widespread adoption.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Postgraduate student, Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, PR China; and Postgraduate student, Oral and Maxillofacial Surgery Teaching and Research Section, School of…
- Associate Professor, Department of Stomatology, No. 971 Hospital of the Chinese Navy, Qingdao, Shandong, PR China.
- Professor, State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, School of Stomatology, The Fourth Military Medical University, Xi'an, PR China.
- Associate Professor, Department of Oral Implantology, The Affiliated Hospital of Qingdao University, Qingdao, PR China; and Associate Professor, Oral and Maxillofacial Surgery Teaching and Research Section, School of St…
Förderung
- Shandong Province Natural Science Foundation
Zitieren
APA
Li, X., Wang, G., Zhao, Y., & Wang, X. (2026). Accuracy of autonomous dental implant robotic system versus static guide-assisted implant surgery in immediate implant placement: A retrospective clinical study. The Journal of Prosthetic Dentistry, 135(4), 771-776. https://doi.org/10.1016/j.prosdent.2025.06.038
Vancouver
Li X, Wang G, Zhao Y, Wang X. Accuracy of autonomous dental implant robotic system versus static guide-assisted implant surgery in immediate implant placement: A retrospective clinical study. The Journal of Prosthetic Dentistry. 2026;135(4):771-776. doi:10.1016/j.prosdent.2025.06.038
BibTeX
@article{Li2026,
author = {Li, Xuehan and Wang, Guowei and Zhao, Yimin and Wang, Xiaojing},
title = {Accuracy of autonomous dental implant robotic system versus static guide-assisted implant surgery in immediate implant placement: A retrospective clinical study},
journal = {The Journal of Prosthetic Dentistry},
year = {2026},
volume = {135},
number = {4},
pages = {771--776},
doi = {10.1016/j.prosdent.2025.06.038}
}
EUVIMED