Role of interproximal contacts in implant-supported crown stability: A finite element analysis study
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.04.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Konstantinos Krommydas und 10 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral student, Laboratory of Biomaterials and Computational Mechanics, Department of Mechanical Engineering, University of Western Macedonia, Koza…. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Dental Implants, Single-Tooth. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Hellenic Foundation for Research and Innovation.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Screw loosening remains a frequent complication with implant-supported prostheses. While clinical evidence suggests that posterior single implant crowns present a high rate of complications, whether the absence of interproximal contacts with adjacent natural teeth is a contributing factor to these complications remains unclear. PURPOSE: The purpose of this finite element analysis study was to evaluate the biomechanical behavior of single implant-supported crowns placed in the posterior mandible. Two variables were investigated: the impact of implant position (first molar versus second molar) and the nature of the interproximal contact with the adjacent teeth (mesial versus mesial and distal interproximal contacts). MATERIAL AND METHODS: Three mandibular models were constructed using microtomography: fully dentate (control), partially edentulous with a missing second molar replaced by a single implant-supported crown (mesial interproximal contact only), and partially edentulous with a missing first molar replaced by a single implant-supported crown (mesial and distal interproximal contacts). The finite element analysis simulated occlusal loading during masticatory function. Stress distribution was evaluated by using the von Mises stress criterion, with principal stress analysis for bone anisotropy. Model validation was performed against experimental tooth displacement data. RESULTS: Implants with both interproximal contacts (first molar position) exhibited more evenly distributed stress and significantly lower stress concentrations on the implant neck compared with the implant with only a mesial interproximal contact (second molar position). The second molar position showed higher stress at the implant-abutment connection. CONCLUSIONS: Implant positioning and the number of interproximal contacts significantly influenced stress distribution and prosthesis stability. Implants placed between natural teeth present a lower risk of screw loosening and enhanced long-term crown stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Doctoral student, Laboratory of Biomaterials and Computational Mechanics, Department of Mechanical Engineering, University of Western Macedonia, Kozani, Greece.
- Researcher, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
- Researcher, Laboratory of Biomaterials and Computational Mechanics, Department of Mechanical Engineering, University of Western Macedonia, Kozani, Greece.
- Resident, Department of Restorative Sciences & Biomaterials, Henry M. Goldman School of Dental Medicine, Boston University, Boston, Mass.
- Resident, Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece.
- Head of Biomedical Engineering, BETA CAE Systems International AG, D4 Business Village Luzern, Root, Switzerland.
Förderung
- Hellenic Foundation for Research and Innovation
Zitieren
APA
Krommydas, K., Papaioannou, E., Karagiannidou, C., Kirmanidou, Y., Rabah, B., Niakou, A., Karatsis, E., Michalakis, P., Pissiotis, A., Michalakis, K., & Tsouknidas, A. (2025). Role of interproximal contacts in implant-supported crown stability: A finite element analysis study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.04.004
Vancouver
Krommydas K, Papaioannou E, Karagiannidou C, Kirmanidou Y, Rabah B, Niakou A, et al. Role of interproximal contacts in implant-supported crown stability: A finite element analysis study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.04.004
BibTeX
@article{Krommydas2025,
author = {Krommydas, Konstantinos and Papaioannou, Efthymia and Karagiannidou, Chrysanthi and Kirmanidou, Yvone and Rabah, Bahaa and Niakou, Athina and Karatsis, Evaggelos and Michalakis, Polychronis and Pissiotis, Argyris and Michalakis, Konstantinos and Tsouknidas, Alexander},
title = {Role of interproximal contacts in implant-supported crown stability: A finite element analysis study},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.04.004}
}
EUVIMED