Effect of finish line designs on the dimensional accuracy of monolithic zirconia crowns fabricated with a material jetting technique
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.02.055 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Jizhe Lyu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Cli…. Hauptthemen laut MEDLINE: Crowns, Zirconium, Dental Prosthesis Design, Dental Materials. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Fujian Medical University, National Natural Science Foundation of China.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Finish line design is critical for the long-term stability of complete crown restorations. However, the optimal finish line design for monolithic crowns fabricated with material jetting (MJ), a type of printed zirconia, remains unknown. PURPOSE: The purpose of this in vitro study was to evaluate the dimensional accuracy and marginal quality of monolithic zirconia complete crowns with various finish line designs fabricated through subtractive manufacturing (SM) or MJ. MATERIAL AND METHODS: A standardized typodont right mandibular first molar was prepared with 5 different finish line designs: knife edge, 0.5-mm chamfer, 0.5-mm shoulder, 0.8-mm chamfer, and 0.8-mm shoulder. Complete crowns were designed with identical occlusal morphology and thickness. In total, 100 monolithic zirconia crowns were fabricated using SM and MJ (n=10 crowns for each finish line design and manufacturing method). Dimensional accuracy in the external, marginal, and intaglio regions was evaluated by using best-fit alignment with the design data. Marginal quality was assessed under a ×20 stereomicroscope. Differences among the test groups were analyzed by using MANOVA and post hoc least significant difference tests for accuracy data, and Scheirer-Ray-Hare test with Dunn post hoc test for margin quality data (α=.05). RESULTS: Significant differences in accuracy were found for the external and marginal regions based on finish line design, and for external accuracy based on the manufacturing method (P .05). MJ crowns exhibited lower external deviations and similar margin and intaglio RMS values compared with SM crowns (P>.05). Marginal quality was highest for the 0.8-mm chamfer and shoulder designs, while knife edge designs exhibited the most flaws, regardless of manufacturing method. CONCLUSIONS: All 5 margin designs demonstrated reliable accuracy in monolithic zirconia crowns. However, crowns with 0.8-mm chamfer and 0.8-mm shoulder designs exhibited superior accuracy and marginal quality compared with knife edge, 0.5-mm chamfer, and 0.5-mm shoulder designs. MJ technology produced crowns showed higher external accuracy than SM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Researc…
- Graduate student, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China.
- Clinical Associate Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China.
- Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology, Beijing, PR China.
- Clinical Professor, Department of Prosthodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Resea…
Förderung
- Fujian Medical University
- National Natural Science Foundation of China
Zitieren
APA
Lyu, J., Cao, X., Yang, X., Tan, J., & Liu, X. (2025). Effect of finish line designs on the dimensional accuracy of monolithic zirconia crowns fabricated with a material jetting technique. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.02.055
Vancouver
Lyu J, Cao X, Yang X, Tan J, Liu X. Effect of finish line designs on the dimensional accuracy of monolithic zirconia crowns fabricated with a material jetting technique. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.02.055
BibTeX
@article{Lyu2025,
author = {Lyu, Jizhe and Cao, Xunning and Yang, Xu and Tan, Jianguo and Liu, Xiaoqiang},
title = {Effect of finish line designs on the dimensional accuracy of monolithic zirconia crowns fabricated with a material jetting technique},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.02.055}
}
EUVIMED