Effects of different fabrication techniques on the marginal gap of interim crowns as assessed by optical coherence tomography: An in vitro study
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.01.030 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Siti Rosma Rosli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate student, Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia. Hauptthemen laut MEDLINE: Crowns, Tomography, Optical Coherence, Computer-Aided Design, Dental Prosthesis Design. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Universiti Malaya.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Studies on the assessment of the marginal fit of interim crowns with optical coherence tomography (OCT) are lacking. PURPOSE: The purpose of this in vitro study was to apply OCT to evaluate and to compare the impact of conventional and computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication methods and different materials, including bis-acryl, conventional polymethyl-methacrylate (PMMA), and CAD-CAM PMMA, on the marginal fit of interim crowns. MATERIAL AND METHODS: Thirty crown specimens were fabricated, with 20 PMMA crowns divided into 2 groups based on the fabrication method: the conventional method (Group Jet, n=10) and the CAD-CAM method (Group CAD-CAM PMMA, n=10). An additional 10 bis-acryl crowns were fabricated using the conventional method (Group Protemp, n=10). The marginal gap was assessed at 8 specific points using swept-source OCT. Comparisons between the fabrication methods of PMMA crowns and different materials of conventionally made crown were done using an independent t test (α=.05). RESULTS: Group CAD-CAM PMMA recorded statistically significant lower total mean vertical marginal gap values (22.2 ±4.7 µm) compared with group Jet (62.6 ±2.2 µm) (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Postgraduate student, Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.
- Senior Lecturer, Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia.
- Associate Professor, Department of Restorative Dentistry, Faculty of Dentistry, Universiti Malaya, Kuala Lumpur, Malaysia. Electronic address: azwatee@um.edu.my.
Förderung
- Universiti Malaya
Zitieren
APA
Rosli, S. R., Radzi, N. D. M., Razak, M. A. A., & Abdul Aziz, A. (2025). Effects of different fabrication techniques on the marginal gap of interim crowns as assessed by optical coherence tomography: An in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.01.030
Vancouver
Rosli SR, Radzi NDM, Razak MAA, Abdul Aziz A. Effects of different fabrication techniques on the marginal gap of interim crowns as assessed by optical coherence tomography: An in vitro study. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.01.030
BibTeX
@article{Rosli2025,
author = {Rosli, Siti Rosma and Radzi, Nur Diyana Mohamed and Razak, Mohd Azmi Abdul and Abdul Aziz, Azwatee},
title = {Effects of different fabrication techniques on the marginal gap of interim crowns as assessed by optical coherence tomography: An in vitro study},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.01.030}
}
EUVIMED