EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of fracture resistance and marginal fit of implant-supported interim crowns fabricated by conventional, additive and subtractive methods

Safaa Salah Elsareef, Amir Shokry Azer, Noha Morsy

BMC Oral Health · 27.07.2024 · 24 (1)

DOI: 10.1186/s12903-024-04597-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift BMC Oral Health, online erschienen am 27.07.2024. Verfasst von Safaa Salah Elsareef und 2 weiteren Autor:innen. Beteiligte Einrichtung: Senior researcher of Fixed prosthodontics, Department of conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. safa…. Hauptthemen laut MEDLINE: Crowns, Dental Prosthesis, Implant-Supported, Dental Prosthesis Design. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alexandria University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Interim crowns are utilized for restoring implants during and after the process of osseointegration. However, studies on adaptation and fracture strength of implant-supported interim crowns are rare. Aim of the study The aim of this in vitro study is evaluating marginal fit and fracture resistance of conventional, subtractive, and additive methods of fabricating implant-supported interim crowns. Materials and methods An implant was placed in an epoxy resin model with a missing first molar. A scan body was attached, and scanned with an intraoral scanner (IOS), the STL file was used to fabricate eighteen master models with standardized implant digital analogue spaces. The digital analogues and their corresponding abutments were attached to the master models and scanned with the IOS, the STL files were used to fabricate eighteen crowns using three different techniques ( n = 6): conventional (CR); from Autopolymerizing composite resin, subtractive (SM); milled from PMMA resin blanks, and additive (AM); from 3D printed resin material. The crowns were fitted and cemented on their corresponding abutments and subjected to cyclic loading and thermocycling. The marginal fit was evaluated using a stereomicroscope. The crowns were then loaded until fractured in a universal testing machine. The Shapiro–Wilk and the Kolmogorov-Smirnov tests revealed that data of Marginal gap was non-parametric. Kruskal-Wallis test followed by the Dunn test was used (α = 0.05). While data of Fracture resistance test was parametric. ANOVA (F-test) was used followed by the Tukey test (α = 0.05).

Results

For marginal gap, a significant difference was shown between the study groups ( P = .001) according to Kruskal–Wallis test. Groups SM and AM had significantly lower marginal gap values compared to group CR ( P = .003). No significant difference was found between groups SM and AM ( P = .994). For fracture resistance, One-way ANOVA revealed a significant difference in fracture resistance between study groups ( P < .001). Group SM had significantly higher fracture strength followed by group AM and group CR ( P = .001).

Conclusions

Group SM and AM showed better marginal adaptation than group CR. Group SM showed superior fracture resistance compared to other groups. All study groups showed acceptable marginal gap and fracture resistance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrownsDental Prosthesis, Implant-SupportedDental Prosthesis DesignHumansIn Vitro TechniquesDental Marginal AdaptationDental Restoration FailureDental Stress AnalysisComputer-Aided DesignMaterials Testing

Stichwörter der Autor:innen

3D printingCAD CAM millingDirect microscopic evaluationImplant-supported interim crowns: fracture resistanceLaboratory analoguesMarginal fit

Autor:innen und Institutionen

  • Senior researcher of Fixed prosthodontics, Department of conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. safaa.elsareef.dent@alexu.edu.eg.
  • Associate professor of Fixed prosthodontics, Department of conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
  • Lecturer of Fixed prosthodontics, Department of conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.

Förderung

  • Alexandria University

Zitieren

APA

Elsareef, S. S., Azer, A. S., & Morsy, N. (2024). Evaluation of fracture resistance and marginal fit of implant-supported interim crowns fabricated by conventional, additive and subtractive methods. BMC Oral Health, 24(1). https://doi.org/10.1186/s12903-024-04597-9

Vancouver

Elsareef SS, Azer AS, Morsy N. Evaluation of fracture resistance and marginal fit of implant-supported interim crowns fabricated by conventional, additive and subtractive methods. BMC Oral Health. 2024;24(1). doi:10.1186/s12903-024-04597-9

BibTeX
@article{Elsareef2024,
  author = {Elsareef, Safaa Salah and Azer, Amir Shokry and Morsy, Noha},
  title = {Evaluation of fracture resistance and marginal fit of implant-supported interim crowns fabricated by conventional, additive and subtractive methods},
  journal = {BMC Oral Health},
  year = {2024},
  volume = {24},
  number = {1},
  doi = {10.1186/s12903-024-04597-9}
}
Kostenlos starten →