Influence of polymerization protocols on the physical and mechanical properties of a 3D printed resin
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2025.01.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Fabio A P Rizzante und 5 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor and Assistant Dean for Innovation, James B. Edwards College of Dental Medicine, Medical University of South Carolina (MUSC), Char…. Hauptthemen laut MEDLINE: Polymerization, Printing, Three-Dimensional, Dental Materials. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Fast prototyped, or 3-dimensionally (3D) printed, materials enhance clinical efficiency when compared with other manufacturing methods. Nevertheless, standardization and information regarding the influence of different postprocessing protocols on the final physical and mechanical properties of 3D printed parts is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the effect of different polymerization methods and times on the flexural strength, microhardness, and color stability of a 3D printed resin (OnX; SprintRay). MATERIAL AND METHODS: A total of 40 disks (Ø10×2 mm) and 40 bars (10×2×2 mm) were 3D printed, washed, and subdivided into 4 groups (n=10) according to the polymerization protocol: VALO Grand light polymerization unit for 40 and 120 seconds (VG40s andVG120s) and ProCure 2 polymerization chamber for 1 and 2 cycles (PC×1 and PC×2). The bars were stored in distilled water at 37 °C for 24 hours, and a 3-point bend test was performed with a universal testing machine with an 8-mm span and a downward movement at a rate of 0.5 mm/minute until fracture. The disks were polished with abrasive disks. Color stability was assessed after polymerization (baseline), after 1 and 7 days in dark, dry storage at 37 °C, and after 3 days of artificial aging in deionized water at 60 °C. Values of b* were used to calculate yellow shift/Δb* values after 3 days of artificial aging. Microhardness after 7 days in dark, dry storage was assessed with a Knoop indenter. The data were assessed for homogeneity using the Levene test and for normality using the Shapiro-Wilk test. Two-way ANOVA (flexural strength, microhardness, and Δb* tests) and 3-way repeated-measures ANOVA (color stability test) were followed by the Tukey HSD post hoc test (α=.05 for all tests). RESULTS: For microhardness, the polymerization unit (P PC×1>PC×2. For flexural strength, the polymerization unit (P VG40s. For color stability, the polymerization unit (P=.009), time (P VG40s=VG120s. Significantly different Δb* was found for polymerization unit (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Associate Professor and Assistant Dean for Innovation, James B. Edwards College of Dental Medicine, Medical University of South Carolina (MUSC), Charleston, SC. Electronic address: rizzante@musc.edu.
- Graduate student, James B. Edwards College of Dental Medicine, Medical University of South Carolina (MUSC), Charleston, SC.
- Assistant Professor, Department of Reconstructive and Rehabilitation Sciences, James B. Edwards College of Dental Medicine, Medical University of South Carolina (MUSC), Charleston, SC.
- Associate Professor, Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo (USP), Bauru, SP.
Zitieren
APA
Rizzante, F. A. P., Azzer, M., Moghaddam, N. G., Watson, T., Moura, G. F., & Furuse, A. Y. (2025). Influence of polymerization protocols on the physical and mechanical properties of a 3D printed resin. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2025.01.006
Vancouver
Rizzante FAP, Azzer M, Moghaddam NG, Watson T, Moura GF, Furuse AY. Influence of polymerization protocols on the physical and mechanical properties of a 3D printed resin. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2025.01.006
BibTeX
@article{Rizzante2025,
author = {Rizzante, Fabio A P and Azzer, Michael and Moghaddam, Nima G and Watson, Thomas and Moura, Guilherme F and Furuse, Adilson Y},
title = {Influence of polymerization protocols on the physical and mechanical properties of a 3D printed resin},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2025.01.006}
}
EUVIMED