EUVIMEDEUVIMED entdecken
Crossref

Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study

Passupang Veerapeindee, Pimduen Rungsiyakull, Wissanee Jia-Mahasap

The Journal of Prosthetic Dentistry · 2025-03 · 133 (3) · 904.e1-904.e8

DOI: 10.1016/j.prosdent.2024.12.006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025-03. Verfasst von Passupang Veerapeindee und 2 weiteren Autor:innen. Beteiligte Einrichtung: Graduate student, Graduate Prosthodontics, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Dental Restoration Wear, Methacrylates, Denture Design. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Chiang Mai University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Three-dimensional (3D) printing and milling technologies have been increasingly used in prosthodontic practice for fabricating digital prostheses. Nevertheless, evidence relating to the wear resistance of denture teeth fabricated using these methods is lacking. PURPOSE: The purpose of this in vitro study was to compare the wear resistance exhibited by denture teeth fabricated using 3D printing and milling technologies with prefabricated denture teeth. MATERIAL AND METHODS: Fifty specimens of resin denture teeth from 3 types of manufacturing processes were prepared and divided into 5 groups: 1 group of 3D printed denture teeth (NextDent C&B MFH), 2 groups of milled denture teeth (Ivotion Dent and VIPI Block), and 2 groups of prefabricated denture teeth (Major Dent and Cosmo HXL). Each group of specimens was occluded with a zirconia antagonist under a 49-N load with thermocycling conditions for 120 000 cycles. The antagonist was horizontally displaced back and forth at a 2-mm distance and a frequency of 1.6 Hz. The quantification of the volume loss and the maximal wear depth of the worn specimens were recorded, while the wear characteristics were assessed with a scanning electron microscope (SEM). Data were analyzed using the Kruskal-Wallis test followed by pairwise comparison tests (α=.05). RESULTS: Significantly different wear depths and volume losses were found among groups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalDental Restoration WearMethacrylatesDenture DesignDental MaterialsTooth, ArtificialIn Vitro TechniquesHumansMaterials TestingDental Stress Analysis

Substanzen

MethacrylatesDental Materials

Autor:innen und Institutionen

  • Graduate student, Graduate Prosthodontics, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand.
  • Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand.
  • Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand. Electronic address: wissanee.j@cmu.ac.th.

Förderung

  • Chiang Mai University

Zitieren

APA

Veerapeindee, P., Rungsiyakull, P., & Jia-Mahasap, W. (2025). Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study. The Journal of Prosthetic Dentistry, 133(3), 904.e1-904.e8. https://doi.org/10.1016/j.prosdent.2024.12.006

Vancouver

Veerapeindee P, Rungsiyakull P, Jia-Mahasap W. Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study. The Journal of Prosthetic Dentistry. 2025;133(3):904.e1-904.e8. doi:10.1016/j.prosdent.2024.12.006

BibTeX
@article{Veerapeindee2025,
  author = {Veerapeindee, Passupang and Rungsiyakull, Pimduen and Jia-Mahasap, Wissanee},
  title = {Wear resistance of 3D printed, milled, and prefabricated methacrylate-based resin materials: An in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  volume = {133},
  number = {3},
  pages = {904.e1--904.e8},
  doi = {10.1016/j.prosdent.2024.12.006}
}
Kostenlos starten →