A method for decontaminating a dental implant and components after abutment screw loosening: A clinical report
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.10.004 ↗Kurz gefasst
Fallbericht in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Chandur P K Wadhwani und 3 weiteren Autor:innen. Beteiligte Einrichtung: Private practice, Bellevue, Wash.; Affiliate Assistant Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, …. Hauptthemen laut MEDLINE: Decontamination, Dental Abutments, Dental Implants, Dental Implants, Single-Tooth. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
Abutment screw loosening is the most common complication in single implant-supported crowns, typically remedied by simply reattaching the restoration, preferably using a new abutment screw. The internal aspect of the implant along with any other components should be decontaminated before reconnection. This clinical report provides information on the appropriate management of the decontamination process, as well as evidence of the foreign material found within the implant body.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Private practice, Bellevue, Wash.; Affiliate Assistant Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.; and Science Director, Foundation for Oral Rehabilitati…
- Private practice, Yardly, Pa.; and Clinical Professor, Department of Periodontics, University of Maryland School of Dentistry, Baltimore, MD.
- Private practice, North Dallas, TX.
- Professor, Department of Restorative Dentistry, University of Washington School of Dentistry, Seattle, Wash.
Zitieren
APA
Wadhwani, C. P. K., Rosen, P. S., Wilson, T. G., & Chung, K. H. (2025). A method for decontaminating a dental implant and components after abutment screw loosening: A clinical report. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.10.004
Vancouver
Wadhwani CPK, Rosen PS, Wilson TG, Chung KH. A method for decontaminating a dental implant and components after abutment screw loosening: A clinical report. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.10.004
BibTeX
@article{Wadhwani2025,
author = {Wadhwani, Chandur P K and Rosen, Paul S and Wilson, Thomas G and Chung, Kwok-Hung},
title = {A method for decontaminating a dental implant and components after abutment screw loosening: A clinical report},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.10.004}
}
EUVIMED