Comparison between selective laser melted and cast removable partial denture frameworks
The Journal of Prosthetic Dentistry · 2025
DOI: 10.1016/j.prosdent.2024.06.025 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Ahmad Maalhagh-Fard und 3 weiteren Autor:innen. Beteiligte Einrichtung: Associate Professor and Director of Faculty Success Program, University of Detroit Mercy School of Dentistry, Detroit, Mich. Electronic address: fard…. Hauptthemen laut MEDLINE: Denture, Partial, Removable, Chromium Alloys, Lasers, Dental Casting Technique. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Yale University.
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Cast cobalt chromium (Co-Cr) frameworks for removable partial dentures may have undesirable micromechanical properties leading to clinical failures. Co-Cr frameworks made by selective laser melting (SLM) may have improved micromechanical properties, but comparative studies are lacking. PURPOSE: The purpose of this in vitro study was to compare the micromechanical properties of SLM for Co-Cr alloys with those produced by conventional casting. MATERIAL AND METHODS: The International Organization for Standardization (ISO) standards were used to determine material constants and failure stress. For flexural testing, 31×11×1.2-mm specimens were cast (n=10) and selective laser melted (n=10) and tested with a 20-mm support span in a 3-point configuration. The cast specimens had been held in a furnace for 5 minutes to encourage dendrite and columnar grain growth to represent the clinical cast RPD framework microstructure at the zone of failure. These failure points were observed with optical and scanning electron microscopy. Three-point bend tests, mimicking the fracture of RPD clasps, were done at room temperature using a universal testing machine (Instron 5569) to characterize the mechanical properties of cast and SLM specimens. The elastic modulus (E), bending yield strength (σy), strain to yield (εy), ultimate flexural stress (σufs), and resilience (Ur) values for the cast and SLM groups were compared using 2-sided t tests (α=.05) and Weibull analysis was completed with the confidence interval of 95%. RESULTS: The SLM and cast Co-Cr groups have statistically significant differences. The SLM mean values for toughness, yield strength, strain to yield, resilience, and strain to failure were statistically higher than the cast mean values (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Associate Professor and Director of Faculty Success Program, University of Detroit Mercy School of Dentistry, Detroit, Mich. Electronic address: fardam@udmercy.edu.
- Private practice, Milford, Mich.
- Clinical Professor, University of Detroit Mercy School of Dentistry, Detroit, Mich.
- Ross School of Business, University of Michigan, Mich.
Förderung
- Yale University
Zitieren
APA
Maalhagh-Fard, A., Ostrander, N. J., Saunders, T. R., & Dadul, T. (2025). Comparison between selective laser melted and cast removable partial denture frameworks. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.06.025
Vancouver
Maalhagh-Fard A, Ostrander NJ, Saunders TR, Dadul T. Comparison between selective laser melted and cast removable partial denture frameworks. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.06.025
BibTeX
@article{MaalhaghFard2025,
author = {Maalhagh-Fard, Ahmad and Ostrander, Nicholas J and Saunders, Timothy R and Dadul, Tenzin},
title = {Comparison between selective laser melted and cast removable partial denture frameworks},
journal = {The Journal of Prosthetic Dentistry},
year = {2025},
doi = {10.1016/j.prosdent.2024.06.025}
}
EUVIMED