EUVIMEDEUVIMED entdecken
Crossref

Effect of shape and design of the internal connection of tissue-level and bone-level implants on detorque values and removal forces: An in vitro study

Amirhossein Fathi, Ramin Mosharraf, Mahsa Ghorbani, Sara Saberipour

The Journal of Prosthetic Dentistry · 2024

DOI: 10.1016/j.prosdent.2024.03.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024. Verfasst von Amirhossein Fathi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Assistant Professor, Dental Materials Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isf…. Hauptthemen laut MEDLINE: Dental Implants, Dental Stress Analysis. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: Isfahan University of Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Optimal implant stability and preventing complications such as screw loosening are paramount concerns for implant-supported prostheses. However, studies examining the influence of various internal connection designs on detorque values and removal forces, critical aspects of implant success, are lacking. PURPOSE: The purpose of this in vitro study was to assess the impact of the shape and design of the internal connection in tissue-level and bone-level implants on the detorque value and the force required for abutment removal from the implant. MATERIAL AND METHODS: Forty dental implants were securely mounted in 10×6×20-mm acrylic resin blocks positioned perpendicular to the surface. The implants were divided into 4 groups (n=10): bone-level SM Torx, tissue-level PSI Torx, bone-level UF Hex, and tissue-level UF Hex implants. After exposure to a dynamic loading test at 31.2 N, 2 Hz and 106 cycles, measurements were made of both detorque values and removal forces. Statistical analyses, including 1-way ANOVA with a post hoc Tukey test and Kolmogorov-Smirnov test, were conducted to assess the results (α=.05). RESULTS: The differences in detorque values among the 4 groups were statistically similar (P=.087). In terms of removal force values, tissue-level PSI implants exhibited the highest values, while bone-level UF implants had the lowest values, with significant differences in the removal forces among the 4 groups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental ImplantsDental Stress AnalysisIn Vitro TechniquesHumansDental Implant-Abutment DesignDental Prosthesis DesignDental Prosthesis, Implant-SupportedDental AbutmentsDental Restoration FailureSurface Properties

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Assistant Professor, Dental Materials Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran. Electronic address: amir_alty@yahoo.com.
  • Professor, Dental Materials Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Graduate student, Dental Research Center, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.
  • Graduate student, Dental Students' Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran.

Förderung

  • Isfahan University of Medical Sciences

Zitieren

APA

Fathi, A., Mosharraf, R., Ghorbani, M., & Saberipour, S. (2024). Effect of shape and design of the internal connection of tissue-level and bone-level implants on detorque values and removal forces: An in vitro study. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.03.001

Vancouver

Fathi A, Mosharraf R, Ghorbani M, Saberipour S. Effect of shape and design of the internal connection of tissue-level and bone-level implants on detorque values and removal forces: An in vitro study. The Journal of Prosthetic Dentistry. 2024. doi:10.1016/j.prosdent.2024.03.001

BibTeX
@article{Fathi2024,
  author = {Fathi, Amirhossein and Mosharraf, Ramin and Ghorbani, Mahsa and Saberipour, Sara},
  title = {Effect of shape and design of the internal connection of tissue-level and bone-level implants on detorque values and removal forces: An in vitro study},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2024},
  doi = {10.1016/j.prosdent.2024.03.001}
}
Kostenlos starten →