Fachartikel in der Zeitschrift Annales Pharmaceutiques Françaises, 2026-07. Verfasst von Hrishikesh Khude und 2 weiteren Autor:innen. Beteiligte Einrichtung: Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, V.L. Mehta Road, Vile Parle (W), Mumbai - 400056, India. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A robust and highly sensitive LC-MS/MS method was developed and validated for the quantification of diosgenin in mice plasma in accordance with ICH M10 guidelines. Chromatographic separation was achieved using Kinetex C8 column (50×2.1mm, 5μm) with 0.1% formic acid in distilled water and methanol as mobile phase at a flow rate of 0.6mL/min, and the run time was 17min. Detection was performed in positive ESI+ mode using MRM at m/z 415.10→271.20, employing sarsasapogenin as the internal standard. Protein precipitation yielded efficient extraction with minimal matrix interference. The method exhibited excellent linearity over 3.125-1000ng/mL (r2=0.996) with an LLOQ of 3.125ng/mL. The accuracy during within-day and between-day evaluations ranged from 91.7% to 110.99%, and precision (%CV) remained below 5.14%. Dilution integrity indicated that the analyte can be reliably quantified in biological samples up to 24,000ng/mL. The stability studies confirmed that the analyte was stable under various conditions. Further, this validated method was applied for pharmacokinetic studies in female mice via oral (10mg/kg) and intramuscular (5mg/kg) administration. Overall, the method is reliable for trace-level quantification and demonstrated its applicability in pharmacokinetic, bioavailability, and formulation studies of diosgenin.

Schlagwörter

Stichwörter der Autor:innen

Bioanalytical validationChromatographic separationPharmacocinétiquePharmacokineticsProtein precipitationPrécipitation des protéinesSéparation chromatographiqueValidation bioanalytique

Autor:innen und Institutionen

  • Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, V.L. Mehta Road, Vile Parle (W), Mumbai - 400056, India.
  • Shobhaben Pratapbhai Patel School of Pharmacy & Technology Management, SVKM's NMIMS, V.L. Mehta Road, Vile Parle (W), Mumbai - 400056, India; Department of Pharmaceutical Technology (Formulations), National Institute of…

Zitieren

APA

Khude, H., Pai, R., & Shende, P. (2026). A highly-sensitive and selective LC–MS/MS platform for quantitative determination of diosgenin in mice plasma with comprehensive bioanalytical validation and pharmacokinetic study. Annales Pharmaceutiques Françaises. https://doi.org/10.1016/j.pharma.2026.07.008

Vancouver

Khude H, Pai R, Shende P. A highly-sensitive and selective LC–MS/MS platform for quantitative determination of diosgenin in mice plasma with comprehensive bioanalytical validation and pharmacokinetic study. Annales Pharmaceutiques Françaises. 2026. doi:10.1016/j.pharma.2026.07.008

BibTeX
@article{Khude2026,
  author = {Khude, Hrishikesh and Pai, Rohan and Shende, Pravin},
  title = {A highly-sensitive and selective LC–MS/MS platform for quantitative determination of diosgenin in mice plasma with comprehensive bioanalytical validation and pharmacokinetic study},
  journal = {Annales Pharmaceutiques Françaises},
  year = {2026},
  doi = {10.1016/j.pharma.2026.07.008}
}
Kostenlos starten →